Run Mode
Additional Controls
Venting
In Max models a Vent Time can be set using the
Advanced Programming mode (page 51). This is typi-
cally done in a Pressure Based System (P1) to allow
injectors to reset.
•
Unit vents for a set amount of time (not dis-
played).
•
The LED's next to C/P1, C/P2, C/P3 flash while
unit is venting.
•
The pump will not run while in Venting mode.
•
If Machine Count is set, the display will alter-
nate between machine counts remaining and
backup While unit is venting, VEnt will display
and alternate with Machine Count and the
Backup Time or the OFF Time.
HH
MM
ON
MM : SS
C
1
P
C
C
2
P
C
P
3
P
F
. 55
IG
Prelube / Prelube Delay
In all models a power OFF/ON cycle can be controlled
with the Prelube and Prelube Delay functions.
Prelube
The Prelube function has been selected. Prelube delay
is set to 00:00:
•
Power to the unit cycles OFF then ON.
•
Unit immediately begins a lubrication cycle.
62
SS
##
!
OFF
HH : MM
1 2 3
•
Max Model - display shows Cycle/Pres-
sure/Backup Time (See Max Model Lubrication
Mode Controls, page 58).
Prelube Delay
The Prelube function has been selected. Prelube delay
is set to something other than 00:00:
•
Power to the unit cycles OFF then ON.
•
Unit immediately begins the Prelube Delay
count down and after the Prelube Delay time
runs out, the lubrication cycle begins.
•
The LED next to the clock in the OFF field is
illuminated (F
. 56).
IG
•
The Prelube LED lights (F
•
The display shows time remaining until lubrica-
tion cycle begins. The example shown in F
56 shows 8 minutes and 14 seconds left until a
lubrication cycle begins.
HH
MM
ON
MM : SS
C
1
P
C
C
2
P
C
P
3
P
F
. 56
IG
Manual Run Cycle
To run an extra (non-programmed) lubrica-
tion cycle, push the Manual Start button.
NOTE: Manual Run option is not available while unit is
in Vent Mode.
. 56).
IG
SS
##
!
OFF
HH : MM
1 2 3
332305R
.
IG