Graco G3-G-24MX-2L0L00-10CV00R0 Instructions Manual page 71

Max automatic lubrication pump
Hide thumbs Also See for G3-G-24MX-2L0L00-10CV00R0:
Table of Contents

Advertisement

Pressure
Fault
HH
MM : SS
Machine
Count
Warning
HH
MM : SS
332305R
MM
SS
##
!
OFF
ON
HH : MM
C
1
P
C
C
1 2 3
2
P
C
P
3
P
MM
SS
##
!
ON
OFF
HH : MM
C
1
P
C
C
1 2 3
2
P
C
P
3
P
Alarms: Firmware Versions 6.02 and Above
In pressure mode indi-
cates that unit is over pres-
surized or a lubrication
cycle was not completed
in the user-defined amount
of time.
LED corresponding to the
affected sensor input
blinks.
Could be more than one
sensor alarm at the same
time.
The unit has not received
the correct number of
machine counts in the user
defined Backup Time.
If the warning condition
clears itself on the next
automatic lubrication
cycle, the warning is
cleared and the unit con-
tinues normal operation.
Examine system to deter-
mine if you have a
plugged or broken line or
other component failure,
i.e., divider valve, injector.
Press and
hold the
RESET but-
ton to clear
fault.
Examine system to deter-
mine if the machine sen-
sor is operating properly.
Press and
hold the
RESET but-
ton to clear
warning.