Models without a follower plate:
1. Connect fill hose to Zerk Inlet Fill Fitting (D) (F
23).
D
F
. 23
IG
2. For higher viscosity fluids, start pump to rotate stir-
ring paddle during fill to prevent air pockets from
forming in grease.
To start the pump press the manual run
button.
3. Fill reservoir with NLGI grease to max
fill line.
NOTE: Vent port, located in rear of reservoir, should not
be used as an overfill port/indicator.
F
. 24
IG
4. Remove fill hose.
332305R
Models with Top Fill
.
IG
MOVING PARTS HAZARD
E
Moving parts can pinch, cut or amputate fingers and
other body parts.
Keep clear of moving parts.
Do not operate equipment with lid removed.
Disconnect power before removing lid.
1. Disconnect the power from the equipment.
NOTE: If battery disconnect is not available, remove the
power cord (F
F
. 25
IG
2. Clean the top of the lid and the area around the top
of the reservoir to ensure that no debris falls into
the reservoir when the lid is removed.
3. Turn the lid counterclockwise to remove.
4. Place the lid in a clean area to avoid debris getting
into the inside of the lid or threads.
5. Fill the reservoir with new clean grease.
6. Make sure that no contaminants enter the reservoir.
. 25).