Sample Error Log
G3 Error Log
DMS ID Number: 00025 (see page 42)
Software Part Number:16F821
Software Version:0205
12/31/2015 23:04:00
Date
Time
Description
12/31/2015 23:03:54 Low Level Cleared
12/31/2015 23:03:42 Low Level Fault
12/31/2015 23:03:32 Low Level Warning
12/31/2015 23:03:22 P2 Not Detected Cleared
12/31/2015 23:03:22 C1 Not Detected Cleared
12/31/2015 23:03:19 P2 Not Detected
12/31/2015 23:03:19 C1 Not Detected
12/31/2015 23:02:20 Machine Count Not Detected
12/31/2015 23:02:11 Machine Count Not Detected
Common Error Log entries are listed below.
Software Fault
Low Level Warning
Low Level Fault
C1 Not Detected
C2 Not Detected
C3 Not Detected
P1 Not Detected
P2 Not Detected
P3 Not Detected
System Already Pres-
surized 1
System Already Pres-
surized 2
System Already Pres-
surized 3
332305R
An internal software error
occurred. Contact Graco Cus-
tomer Service.
The unit entered a low level
warning mode and is running
low on material. The pump
continues to dispense mate-
rial for the duration of the low
level alarm time specified by
the unit.
The alarm time in low level
warning has elapsed. The unit
will not pump until the reser-
voir is filled and the fault is
cleared.
In a divider valve system, the
system has not received the
programmed number of
divider valve cycles for the
specified input in the pro-
grammed backup time.
In an injector system the sys-
tem has not received a signal
from the pressure switch in the
designated backup time.
In an injector system the pres-
sure switch is activated when
the unit enters a pump on
mode and may not have
vented properly.
Machine Count Sen-
sor Failure
Motor Overcurrent
High Temperature
Warning
Low Temperature
Warning
USB Unable to Mount The USB flash drive that was
USB Unsupported
Device
USB File Not Found
USB Folder Naviga-
tion
USB Invalid File
Failed Pin Code Entry A failed attempt was made to
Operation / Data Log
The specified number of
machine count input activa-
tions was not received within
the designated backup time.
The unit is out of expected
motor current range. Check
the system to determine that it
is functioning correctly (i.e., no
blocked lines). Continued
operation at excessive motor
currents will cause degrada-
tion in pump life.
Internal temperature of the unit
is above the designated oper-
ating. Check the unit and sys-
tem to determine that it is
functioning correctly. Operat-
ing outside of the specified
temperature range may cause
reduced performance and
possible unit failure.
Internal temperature of the unit
is below the designated oper-
ating. Check the unit and sys-
tem to determine that it is
functioning correctly. Operat-
ing outside of the specified
temperature may cause
reduced performance and
possible unit failure.
installed was unable to con-
nect and communicate with
the pump.
The USB flash drive is unsup-
ported. Use a different flash
drive.
The pump program setting file
was not found or created cor-
rectly. Restore the setting file
to the flash drive.
The pump program setting file
was not found or created cor-
rectly. Restore the setting file
to the flash drive.
The pump program settings
file was not found or created
correctly. Restore the setting
file to the flash drive.
enter the pin code password.
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

G3-g-24mx-2lfl00-10cv00r0G3-g-acmx-2l0l00-1d0v0000G3-g-acmx-2lfl00-1d0v0000G3-g-12mx-2l0l00-1dmva2r3G3-g-24mx-2l0l00-1dmva2r3G3-g-24mx-2lfl00-1dmva2r3 ... Show all

Table of Contents