Alarm Output and Remote Illumination Response
The following tables include graphical representations of the connector as it appears on the unit, a pin-out associ-
ated with the connector and a typical installation wiring diagram. An internal representative wiring diagram is
included where it is deemed useful.
Wire colors provided on these pages only refer to the power cable provided by Graco with this product.
See Advanced Menu Options A7, A9, or A11 to modify the behavior of the alarm output or low level output.
Unit in OFF Mode
Unit in ON Mode
Warning Condition
Fault Condition
Outputs ("08" option) (via 5 wire CPC)
Low Level Warning
Low Level Fault
332305R
Alarm Output
(via DIN alarm relay
connector)
Deactivated (off)
Deactivated (off)
Activated (on)
Toggles On and Off once
per second
Activated (On)
Toggles On and Off once per second
Standard Remote
Illumination
(via 5 wire CPC power
cable)
Off
On
Toggles On and Off once
per second
Toggles On and Off once
per second
Pin 4
Alarm
Activated (On)
Activated (On)
Installation
Tri-Color Remote
Illumination
(via M12 Connector)
Off
Green
Yellow
Red
Pin 7
Low Level
15