Graco G3-G-24MX-2L0L00-10CV00R0 Instructions Manual page 37

Max automatic lubrication pump
Hide thumbs Also See for G3-G-24MX-2L0L00-10CV00R0:
Table of Contents

Advertisement

2. When
OFF is on
the dis-
play,
press the
ENTER
button to save selection.
If the sensor inputs are available and none are used in
the ON Mode, the definition of the entered time is ON
TIME.
Examples:
Model G3-G-24MX-2LFL00-1DMVA2R3 has 4 sensors,
so C/P1, C/P2, and C/P3 and Machine Count can all be
programmed.
Model G3-G-24MX-2LFL00-10CV00R0 has 1 sensor,
only C/P1 is available for programming.
Backup Time
In both Cycle and Pressure Modes, a maximum run
Time (Backup Time) for the lubrication period must be
set up. If this Time expires before the lubrication is
completed an alarm/warning is triggered and the pump
stops.
To determine the Backup Time, Graco recommends the
user verify the length of time it takes to complete a typ-
ical cycle and double that value (to a maximum of 30
minutes).
Backup Time is setup after Cycle or Pressure Sensor
Setup is complete.
NOTE:
The LED next to the clock in the ON field lights,
indicating the Backup Time is being programmed.
BACKUP (ON) Time is set as minutes and seconds
(MM:SS) only.
The small flashing LED under the MM indicates you
are setting minutes.
The first field (left side of display) blinks indicating
the device is ready for you to begin programming.
332305R
Program Backup Time
NOTE: When programming a time of less than 10 min-
utes you must program the leading zero in the first
number field and press the ENTER button to save the
zero selection.
1. To set the ON Time use the
UP or DOWN ARROW button
to scroll through numerals 0
to 5 until the desired number
appears in the first MM (min-
utes) field.
2. Press the ENTER button to lock in the
selection. The next MM number field to
the right flashes indicating it is ready for
programming.
3. Use the UP or DOWN
ARROW button to scroll
through numerals 0 to 9 until
the desired number appears
in the second MM number
field.
4. Press the ENTER button to lock in the
selection.
The next number field to the right
flashes and the LED lights under SS; indicating it is
ready to program the seconds fields.
5. Repeat steps 1 - 4 to set the SS (seconds) fields.
6. After pressing the ENTER button to set
the last SS field, all the programmed ON
Time information is saved.
The G3 automatically switches to the OFF Time
SETUP MODE.
ON Time
The LED next to the clock in the ON
field lights, indicating you are setting
the ON Time parameters.
ON Time is set in Minutes and Seconds (MM: SS).
Max Model Setup
37

Advertisement

Table of Contents
loading

This manual is also suitable for:

G3-g-24mx-2lfl00-10cv00r0G3-g-acmx-2l0l00-1d0v0000G3-g-acmx-2lfl00-1d0v0000G3-g-12mx-2l0l00-1dmva2r3G3-g-24mx-2l0l00-1dmva2r3G3-g-24mx-2lfl00-1dmva2r3 ... Show all

Table of Contents