NOTE: After the Machine Count value is entered, the
G3 can be programmed to backup the machine count
input with time.
Backup Time Setup
1. The OFF Time LED lights.
OFF displays.
2. Press the UP or
DOWN ARROW but-
ton to change OFF to
RUN or FLT on the
display.
RUN: After
backup time
expires the
pump automati-
cally goes into an
ON cycle and
shows a machine
count warning.
FLT: After
backup time
expires, the
pump automati-
cally goes into a
fault mode.
3. Press the ENTER button to set the
selection.
Backup Time
The LED next to the clock in the OFF
field lights, indicating you are setting
the Backup Time parameters.
OFF Time is set in Hours and Minutes
(HH: MM).
332305R
An LED flashes under
either HH when pro-
gramming hours OR
MM when program-
ming minutes.
In SETUP MODE the
number displayed in
the first field, on the
left side of display
blinks, indicating the
device is ready to pro-
gram the Backup Time hours.
The total amount of Backup Time
must be at least twice as long as the
programmed ON Time. If a value less
than twice the ON Time is entered, the
RED alarm LED lights and the value must be
updated.
If this time does not meet the application needs,
contact Graco Customer Support.
Program Backup Time
NOTE: When programming a Backup Time of less than
10 hours you must program a leading zero in the first
number field and press the ENTER button to save the
zero selection.
1. To set the Backup Time use
the UP or DOWN ARROW
button to scroll through
numerals 0 to 9 until the
desired number appears in
the first HH (hour) field.
2. Press the ENTER button to lock in the
selection. The next HH number field to
the right flashes indicating it is ready for
programming.
3. Use the UP or DOWN
ARROW button to scroll
through numerals 0 to 9 until
the desired number appears
in the second HH number
field.
4. Press the ENTER button to lock in the
selection.
The next number field to the right
flashes and the LED lights under MM; indicating it is
ready to program the minutes fields.
Max Model Setup