No.
Meaning of "Event xx" (Example: Event 1)
156
Turns On DET #4 makeup gas.
157
Turns On DET #4 H2.
158
Turns On DET #4 Air.
Turns On CAR1 gas saver.
Sets split ratio to value of CAR1 gas saver split
161
ratio 1.
When GC becomes ready, split ratio returns to
value of analysis parameter.
Turns On CAR1 gas saver.
Sets split ratio to value of CAR1 gas saver split
162
ratio 2.
When GC becomes ready, split ratio returns to
value of analysis parameter.
Turns On CAR2 gas saver.
Sets split ratio to value of CAR2 gas saver split
163
ratio 1.
When GC becomes ready, split ratio returns to
value of analysis parameter.
Turns On CAR1 gas saver.
Sets split ratio to value of CAR2 gas saver split
164
ratio 2.
When GC becomes ready, split ratio returns to
value of analysis parameter.
Turns On CAR1/CAR2/CAR3 high pressure
171
injection mode.
181
Turns On APC1 flow controller.
182
Turns On APC2 flow controller.
183
Turns On APC3 flow controller.
184
Turns On APC4 flow controller.
185
Turns On APC5 flow controller.
186
Turns On APC6 flow controller.
187
Turns On APC7 flow controller.
188
Turns On APC8 flow controller.
189
Turns On APC9 flow controller.
190
Turns On APC10 flow controller.
191
Turns On APC11 flow controller.
192
Turns On APC12 flow controller.
193
Turns On APC13 flow controller.
194
Turns On APC14 flow controller.
195
Turns On APC15 flow controller.
196
Turns On APC16 flow controller.
197
Turns On APC17 flow controller.
198
Turns On APC18 flow controller.
Meaning of "Event-xx" (Example: Event -1)
Turns Off DET #4 makeup gas.
Turns Off DET #4 H2.
Turns Off DET #4 Air.
Turns Off CAR1 gas saver.
Returns
split
ratio
to
parameter.
Turns Off CAR1 gas saver.
Returns
split
ratio
to
parameter.
Turns Off CAR2 gas saver.
Returns
split
ratio
to
parameter.
Turns Off CAR2 gas saver.
Returns
split
ratio
to
parameter.
Turns Off CAR1/CAR2/CAR3 high pressure
injection mode.
Returns column input pressure to value of
analysis parameter.
Turns Off APC1 flow controller.
Turns Off APC2 flow controller.
Turns Off APC3 flow controller.
Turns Off APC4 flow controller.
Turns Off APC5 flow controller.
Turns Off APC6 flow controller.
Turns Off APC7 flow controller.
Turns Off APC8 flow controller.
Turns Off APC9 flow controller.
Turns Off APC10 flow controller.
Turns Off APC11 flow controller.
Turns Off APC12 flow controller.
Turns Off APC13 flow controller.
Turns Off APC14 flow controller.
Turns Off APC15 flow controller.
Turns Off APC16 flow controller.
Turns Off APC17 flow controller.
Turns Off APC18 flow controller.
17 Printing
17.4 Event No.
value
of
analysis
value
of
analysis
value
of
analysis
value
of
analysis
GC-2010 Plus
283