• Keep the inlet valve closed (6) and depressurize the
tank or cooling coil by touching the DISPENSING icon.
• Sanitization should be carried out with new pre-filters
that have been properly pre-installed and the carbon
dust properly removed from the pre-filters.
• Use single-use latex gloves to handle sanitizing pro-
ducts.
• Insert the dosing housing into the inlet pipe of the
equipment.
To this end:
• Disconnect the inlet pipe to the unit marked "IN", and
insert the dosing housing between the inlet valve and
the water inlet of the unit (8). For convenience and ease
of access during sanitizing and opening and closing ope-
rations of the inlet valve, if the valve is inaccessible or at
a great distance from the unit, a manual valve in closed
position can be inserted together with the sanitizing
dosing housing, which will perform the same functions
as the unit's inlet valve.
• Once the assembly is installed, keep the new inlet val-
ve closed and open the inlet valve (9). The dosing hou-
sing must initially be empty.
• Pour 50 ml of sanitizing product into the dosing hou-
sing inserted in the inlet of the unit (10). Screw the hou-
sing correctly to its cap.
• The manual inlet valve must be closed. Connect the
equipment to the power supply.
• Open the water inlet valve to the equipment, allowing
the sanitizing product to flow into the equipment. Keep
the inlet valve in this position and draw a glass of water
from each dispenser, in order to fill the entire hydraulic
circuit with the sanitizing solution.
• Close the inlet valve (11) and let the filters be soaked
with the sanitizing solution and stand for 20 minutes.
In the meantime proceed to sanitize dispensers using
sanitizing spray and paper towels.
• Depressurize the circuit by opening the dispensing
tap. Empty the dosing housing. Before opening it, have
a container within reach where you can empty it, as it
may be full of water.
8
CERRADA
10
• Remove the accessories used for sanitization and
reconnect the feeding tube to the inlet (IN) of the
unit.
• Open the inlet valve and draw 5 liters of water from
each dispenser in order to rinse the sanitizing solu-
tion circuit.
• Use the sanitizing product detector strips to verify
that the equipment is properly flushed, make the
necessary rinses in
9
ABIERTA
CERRADA
11