INDEX Main characteristics Presentation Introduction Technical featuring Unpacking and contents Preliminary warnings Installation of the système Commissioning Maintenance and disinfection Troubleshooting Warranty Installation register Maintenance service Notes...
USER GUIDE FOR SOFTENERS 0. MAIN CHARACTERISTICS ELECTRONIC PROGRAMMERSMART EFFICIENT CONTROL VOLUMETRIC INTELLIGENT REGENERATIONS MIXING VALVE REGULATES THE RESIDUAL HARDNESS BY-PASS INTEGRATED ISOLATED SYSTEM ELECTRONIC ADAPTER MORE SAFETY AND EFFICIENCY BRINE TANK EASY ACCESS SPECIAL FOR SOFTENERS MULTILINGUAL PROGRAMMER LANGUAGES AVAILABILITY ALT ALARM ALT LEVEL...
1. PRESENTATION 1.2. BEFORE STARTING See Section 5 before installing the softener. Follow the The softener you have purchased is a state-of-the-art installation instructions carefully. (Warranty will not be softener with one of the most advanced control heads applicable in case of faulty installation). on the market..
Page 6
The combination of hard minerals and soap produces a During the curing process, water enters the multi-way valve through the inlet fitting, flows up the bottle throu- soap curd or cut soap. This cut soap reduces the clea- ning action of the soap. gh the upper nozzle, passing through the resin bed downwards, thus producing an exchange of ions.
Page 7
In case of higher hardness on the installation, contact Slow washing: This is a movement through the resin bed, of the pre- after-sales service to properly adjust the equipment. viously aspirated brine solution. In this way, the contact Likewise, the maximum hardnesses indicated in chapter of the brine with the resin is maximized, optimizing its 3 must be taken into account.
3. TECHNICAL CHARACTERISTICS The systems are designed to provide fully softened wa- ter; the control valve incorporates a residual hardness mixer to adjust the degree of hardness of the softened water (see section 7). Type of system CAUTION: for water intended for human con- sumption, a residual hardness between 5 and Code: 8ºHF is recommended when the pipes are made of co-...
Page 9
MEDDALSOFT MEDDALSOFT MEDDALSOFT 960489 960490 960488 22 litros 30 litros 11 litros 10x24 10x33 10x13 1,7m 0,8m 2,0 m 2,3 m 1,4 m 1,1 Kg Sal 1,5 Kg Sal 0,55 Kg Sal 64ºHFxm 120ºHFxm 31ºHFxm 2,2 Kg Sal 3,0 Kg Sal 1,1 Kg Sal 95ºHFxm 132ºHFxm...
4. UNPACKING AND CONTENTS If the water to be treated does not come from the mu- nicipal public network or is of unknown origin, it will be necessary to carry out a physico-chemical and bacte- It is important that before the installation and commis- riological analysis of the water, in order to ensure that sioning of the equipment, to check the material recei- it is properly potabilized by applying the techniques and...
• The place provided for its installation must have su- fficient space for the device itself, its accessories, its 5.3 COMMISSIONING AND MAINTENANCE connections and for correct maintenance. The equipment must be disinfected periodically. To see • The equipment must not be installed next to a heat Section 8 for more information.
Page 12
6.2 INSTALLATION STEP BY STEP CAUTION: Do not place shims directly under the salt reservoir. The weight of the tank loaded with 1. The equipment must always be installed with the su- water and salt can cause the tank to burst against pplied bypass valve.
Page 13
PVC plastic pipe Service : the message displayed on the screen alterna- tes between the following information (only for consul- 1. Clean, prepare and glue all seams following manufac- tation, not modifiable). See Section 6.5. turer’s instructions. • Regeneration: Indicates the regeneration stage the equipment is in and the time remaining for it to com- Follow the plumbing manufacturer’s instructions when plete.
Page 14
USER PROGRAMMING ACCESS: Press “MENÚ” during 5 seconds and: “MENÚ” Description Format Hour 0-24 h Year 2019 Month En-Feb. 01-31 ºHF 1-9 Hardness Inhabitants Cap. hight Salt dose Origin Network Regeneration hour 02:00 Charging fault DO NOT TOUCH Programming Notes: •...
Page 15
1. Selecting regeneration parameter. 1. Selection parameter lack salt. 1. Regeneration days Edition. 2. Regeneration edition. 2. Edit salt alert mode. 2. Salt consumption edition. 2:00 Hora regen. Días regen.D ías semana Consumo salC apacidad Menú avanzado MENU CONFIRM DOWN 1.
7. COMMISSIONING 13. The equipment must draw water from the brine tank. Let the suction continue for a few minutes. 14. Undo remaining regeneration steps. 7.1.HYDRAULIC START-UP 15. Put the by-pass in the service position and check that the treated water is correctly softened. Before proceeding, check that all the previous assembly 16.
CAUTION: the hardness regulator is supplied tota- lly closed, if the equipment is not regulated it will supply totally softened water. 8. MAINTENANCE AND DISINFECTION Press For correct operation of the system, carry out the fo- llowing checks: Checking Period Salt level in the tank Monthly Hardness of the water supply...
Page 18
A small bag of Clean Softener in the chimney CAUTION: Follow the instructions for use of the product carefully. Extended equipment shutdowns: A complete regeneration must be initiated if the sof- tener has been out of service for periods exceeding 96 hours.
9. TROUBLESHOOTING PROBLEM PROBABLE CAUSE ACTION 1. The programmer 1. Transformer disconnected. 1. Plug the transformer into an electrical does not work 2. Defective power cord. socket. 3. Lack of power supply. 2. Replace the cable. 4. Defective transformer. 3. Check the installation 4.
10. WARRANTY · The distributor guarantees the equipment for a period of two years for issues with conformity that is detected during this pe- riod, pursuant to RD 1/2007 of 16 November (Consolidated text of the General Law for the Defense of Consumers and Users). The warranty includes the reparation and substitution of defective pieces by authorised personal by the Distributor or the Official Technical Assistance Service (SAT), where it was installed or in a workshop.
11. INSTALLATION REGISTRATION SHEET NOTES FOR THE TECHNICIAN/INSTALLER: Read this Manual carefully. If you have any doubts, get in touch with the Tech- nical Assistance Service (T.A.S) of your distributor. The data market with * must be filled by the installing technical and transcribed in the WARRANTY SHEET.
12. MAINTENANCE SERVICE DATE SERVICE TYPE NAME, SIGNATURE AND TECHNICIAN STAMP START-UP FULL MAINTENANCE TECHNICIAN PREPARATION STAMP ORDINARY HYGIENISATION EXTRAORDINARY OTHER WARRANTY FULL MAINTENANCE TECHNICIAN PREPARATION STAMP ORDINARY HYGIENISATION EXTRAORDINARY OTHER WARRANTY FULL MAINTENANCE TECHNICIAN PREPARATION STAMP ORDINARY HYGIENISATION EXTRAORDINARY OTHER WARRANTY FULL MAINTENANCE...
Page 23
12. MAINTENANCE SERVICE DATE SERVICE TYPE NAME, SIGNATURE AND TECHNICIAN STAMP START-UP FULL MAINTENANCE TECHNICIAN PREPARATION STAMP ORDINARY HYGIENISATION EXTRAORDINARY OTHER WARRANTY FULL MAINTENANCE TECHNICIAN PREPARATION STAMP ORDINARY HYGIENISATION EXTRAORDINARY OTHER WARRANTY FULL MAINTENANCE TECHNICIAN PREPARATION STAMP ORDINARY HYGIENISATION EXTRAORDINARY OTHER WARRANTY FULL MAINTENANCE...
Need help?
Do you have a question about the MEDDALSOFT 11 and is the answer not in the manual?