ACCULINK 3172 and 3174 E1 DSU/CSU
7. When you press F3 from the NET Registers
screen, the interval screen appears. Use this screen
to choose the specific 15-minute interval.
NET Intvl: 01
Up
F1
8. Use the
and
under the first or second digit in the interval
number displayed, then use the F1 (Up) and
F2 (Down) keys to increment/decrement the
number.
9. When you have selected the number of the
interval you want to display, press F3 (Dsply) to
display the registers for the interval selected.
NET Intvl: nn
ES=xxx
F1
10. Use the scroll keys to view additional register
information.
You can reset the network registers from the E1
DSU/CSU via the ClrReg command in the Control branch
of the front panel menu.
To clear the user performance registers:
"
Procedure
1. Press the
key on the top-level menu screen to
bring the Ctrl branch onto the front panel LCD.
DSU E1 CEPT
Stat
F1
4-6
Down
Dsply
F2
F3
keys to position the cursor
F2
F3
Test
Cnfig
F2
F3
2. Press F3 to select Ctrl from the top-level display
screen.
3. Select ClrReg.
4. From the Clear Prf Regs screen, press F1 to clear
the NET registers.
If you selected NET, the network performance
registers are cleared. All accumulators are reset to
zero and all status registers are cleared, and the
current interval timer, the number of valid
intervals count and the total 24-hour counts are
reset to zero. The Command Complete screen then
appears.
March 1999
DSU E1 CEPT
Test
Cnfig
Ctrl
F3
F1
F2
Control:
Rel
LED
ClrReg
F1
F2
F3
Clear Prf Regs:
NET
Prt1
Prt2
F1
F2
F3
Clear NETRegs:
Command Complete
F1
F2
F3
3170-A2-GB20-30