Enterprise Specific Traps. Specifies whether enterpriseSpecific traps are enabled. For more information, refer to the
SNMP Traps section in Chapter 4, Maintenance .
Enab – Sends trap messages for enterpriseSpecific events to the currently configured trap manager(s).
Disab – Disables the sending of trap messages for enterpriseSpecific events.
NOTE: This configuration option is not available and does not appear if the
Alarm Configuration Options section) is disabled.
Link Trap: Both
Next
Disab
Up
Down
Link Trap Type. Specifies the link trap type to enable. Interfaces monitored for linkUp and linkDown traps can be specified
with the Trap I/F configuration option. For more information, refer to the SNMP Traps section in Chapter 4, Maintenance .
Disab – Disables the sending of trap messages for linkDown or linkUp events.
Up – Sends trap messages for linkUp events to the currently configured trap manager(s).
Down – Sends trap messages for linkDown events to the currently configured trap manager(s).
Both – Sends trap messages for linkUp and linkDown events to the currently configured trap manager(s).
NOTE: This configuration option is not available and does not appear if the
Alarm Configuration Options section) is disabled.
Trap I/F: All
Next
NET
DTE
E1s
Link Trap Interfaces. Specifies which interfaces generate linkUp and linkDown trap messages. These traps are supported
on the E1 interfaces (network and DTE Drop/Insert) and the synchronous data ports.
NET – Sends trap messages for linkUp and linkDown events occurring on the network interface.
DTE – Sends trap messages for linkUp and linkDown events occurring on the DTE Drop/Insert interface. This selection is
not displayed if the DTE Drop/Insert interface is disabled.
E1s – Sends trap messages for linkUp and linkDown events occurring on either the network or DTE Drop/Insert interface.
Ports – Sends trap messages for linkUp and linkDown events occurring on the synchronous data ports.
All – Sends trap messages for linkUp and linkDown events occurring on the network interface, DTE Drop/Insert interface,
or the synchronous data ports.
NOTE: This configuration option is not available and does not appear if the Link Trap configuration option is not
configured to generate trap messages for linkUp or linkDown events.