Siemens SITRANS TDL Compact Operating Instructions page 29

In situ laser gas analyzers
Hide thumbs Also See for SITRANS TDL:
Table of Contents

Advertisement

Incorrect selection of type of protection
This device is approved for several types of protection.
1. Decide in favor of one type of protection.
2. Connect the device in accordance with the selected type of protection.
3. In order to avoid incorrect use at a later point, make the types of protection that are not
NOTICE
Ambient temperature too high
Damage to cable sheath.
• At an ambient temperature ≥ 60 °C (140 °F), use heat-resistant cables suitable for an
NOTICE
Condensation in the device
Damage to device through formation of condensation if the temperature difference
between transportation or storage and the mounting location exceeds 20 °C (36 °F).
• Before taking the device into operation, let the device adapt for several hours in the new
Eliminating or reducing the sources of ignition within the equipment
Potential fire hazard.
• The product must be connected to an energy-limited circuit.
• Connect the device according to the information in Connecting SITRANS TDL (Page 30).
Note
Electromagnetic compatibility (EMC)
You can use this device in industrial environments, households and small businesses.
Metal enclosures ensure improved electromagnetic protection from high frequency radiation.
This protection can be increased by grounding the enclosure.
SITRANS TDL
Compact Operating Instructions, 05\2023, A5E51659183-AA – revised 03/2024
WARNING
used permanently unrecognizable on the nameplate.
ambient temperature at least 20 °C (36 °F) higher.
environment.
WARNING
Connecting
6.1 Basic safety notes
29