UTILITY MENU (u + NUMBER)
u7
Stopwatch Mode
You can measure the maximum and
minimum values of the rotation time
of screw fastening. Perform several
measurements because there are
variations in the measured values due
to screw length and rotation speed.
• In stopwatch mode, fastening detection
is disabled.
• Even while you are in stopwatch mode,
you can configure settings in the utility
menu.
• To exit stopwatch mode, set it to "_ _"
again.
Operations while you are in stopwatch mode
▲ button: Displays the maximum value of
▼ button: Displays the minimum value of
OK button: Redisplays the latest measured data.
■ Setting Procedure
Switch to setting mode.
Set the forward/reverse lever to
the trigger switch lock position, and
hold down the OK button.
Choose "u7" by pressing
the ▲ and ▼ buttons, and
press the OK button.
A set value appears on the display.
Select a desired one by
pressing the ▲ and ▼
buttons.
The default is "_ _".
Display
38
EN
rotation time.
rotation time.
Stopwatch Mode
OFF
ON
In stopwatch mode, the screw fastening
time (in seconds) is displayed on the
display.
▲ button held down: Resets the
▼ button held down: Deletes the previous
Press the OK button to
confirm it.
When the setting is completed, a
P. 22
buzzer sounds long (a long beep),
and the display returns to the menu
screen.
Back to Operation Mode.
Hold down the OK button.
(cont.)
0.5
While you are in stopwatch
mode, the detection lamp
blinks cyan.
maximum and
minimum values.
data.