COUNT MENU (c + NUMBER)
c6
Ignore Count Time Setting
You can set screws not to be counted
even if they are fastened again after
being determined as OK.
Set the duration of fastening to exclude
from counting after fastening is
determined as OK.
• Counting is still enabled when you reverse
rotations to redo or loosen screws.
• When both the "
Time Setting" and the "
Fastening Time Setting" are enabled, the
u6
"
Disable Fastening Time Setting"
takes precedence.
■ Setting Procedure
Switch to setting mode.
Set the forward/reverse lever to
the trigger switch lock position, and
hold down the OK button.
Choose "c6" by pressing
the ▲ and ▼ buttons, and
press the OK button.
A set value appears on the display.
Select a desired one by
pressing the ▲ and ▼
buttons.
The default is "-.-".
Display
30
EN
c6
Ignore Count
Disable
u6
P. 37
P. 22
Ignore count time
OFF
0.1 s
9.9 s
(cont.)
Fastening OK
Fastening is
executed during
the set time.
After being determined as OK, screws will not
be counted during the time to ignore counting
even if they are fastened again.
Press the OK button to
confirm it.
When the setting is completed, a
buzzer sounds long (a long beep),
and the display returns to the menu
screen.
Back to Operation Mode.
Hold down the OK button.
P. 22
Count