c5
Ignore Judgement Time Setting
You can exclude unexpected rotations
that are unrelated to work, such as brief
idling and screw hole alignment in push
start mode, from detection.
Set the duration of rotations to exclude
from detection.
■ Setting Procedure
Switch to setting mode.
Set the forward/reverse lever to
the trigger switch lock position, and
hold down the OK button.
Choose "c5" by pressing
the ▲ and ▼ buttons, and
press the OK button.
A set value appears on the display.
Select a desired one by
pressing the ▲ and ▼
buttons.
The default is "-.-".
Display
Ignore judgement time
When it is set to "0.3"
Rotations within 0.3 s are excluded from
fastening detection.
P. 22
OFF
0.1 s
9.9 s
Ignore
Judgement
Rotations within 0.3 s
Press the OK button to
confirm it.
When the setting is completed, a
buzzer sounds long (a long beep),
and the display returns to the menu
screen.
Back to Operation Mode.
Hold down the OK button.
P. 22
29