u4
Rotation Time-based Detection Setting
You can determine whether or not a
screw is properly fastened based on the
rotation time taken to fasten the screw.
Set the lower and upper limits for the
fastening time to be determined as OK.
The optimum rotation time can be
measured in " u7 Stopwatch Mode".
P. 38
• The lower limit setting must not be higher
than the upper limit setting.
■ Setting Procedure
Switch to setting mode.
Set the forward/reverse lever to
the trigger switch lock position, and
hold down the OK button.
Choose "u4" by pressing
the ▲ and ▼ buttons, and
press the OK button.
A set value appears on the display.
Select a desired one by
pressing the ▲ and ▼
buttons.
The lower limit of the rotation time
can be set.
The default is "-.-".
If detection based on the lower limit
is unnecessary, set it to "-.-".
Display Rotation detection time (Min)
When the lower limit and the upper limit
are set to 0.3 and 0.6 respectively
Snugs in 0.1 s
Fastening is determined as OK when the
rotation time is between 0.3 s and 0.6 s before
snugging.
P. 22
OFF
0.1 s
9.9 s
Fastening
NG
(NOK)
Snugs in 0.5 s
Press the OK button to
confirm it.
When the setting is completed, a
buzzer sounds long (a long beep).
Select a desired one by
pressing the ▲ and ▼
buttons.
The upper limit of the rotation time
can be set. The default is "-.-".
If detection based on the upper
limit is unnecessary, set it to "-.-".
Display Rotation detection time (Max)
Press the OK button to
confirm it.
When the setting is completed, a
buzzer sounds long (a long beep),
and the display returns to the menu
screen.
7
Back to Operation Mode.
Hold down the OK button.
Fastening
Fastening
NG
OK
(NOK)
Snugs in 0.8 s
OFF
0.1 s
9.9 s
P. 22