UTILITY MENU (u + NUMBER)
u3
Soft Snug Speed Level Setting
The speed of soft snug can be set.
The start time of soft snug should be
set in " u1 Soft Start & Soft Snug Time
Setting".
P. 32
• Because of the structure of the motor,
it requires some time to decrease the
normal speed to the speed of soft snug.
■ Setting Procedure
Switch to setting mode.
Set the forward/reverse lever to
the trigger switch lock position, and
hold down the OK button.
Choose "u3" by pressing
the ▲ and ▼ buttons, and
press the OK button.
A set value appears on the display.
Soft snug speed level (Rotations/minute)
Display
EYADA218XC
EYADA212XC
EYADA407XC
* Relative to the maximum
number of rotations
Display
EYADA218XC
EYADA212XC
EYADA407XC
* Relative to the maximum
number of rotations
• The values (numbers of rotations) are only guidelines.
34
EN
P. 22
Level1
Level2
450
300
160
About 25%
Level6
Level7
1200
800
430
About 75%
(cont.)
When it is set to "04"
Select a desired one by
pressing the ▲ and ▼
buttons.
The default is "10".
Press the OK button to
confirm it.
When the setting is completed, a
buzzer sounds long (a long beep),
and the display returns to the menu
screen.
Back to Operation Mode.
Hold down the OK button.
Level3
600
750
400
500
220
270
Level8
1350
1500
900
1000
490
540
During the time set
for soft snug, a screw
is fastened slowly
at about 50% of the
maximum speed.
P. 22
Level4
Level5
900
600
330
About 50%
Level9
Level10
1650
1100
600
About 100%
1050
700
380
1800
1200
650

Advertisement