c3
Count Return Setting
You can set how fastened screws
determined as OK are counted
when reversing rotations to redo or
loosen them.
■ Setting Procedure
Switch to setting mode.
Set the forward/reverse lever to
the trigger switch lock position, and
hold down the OK button.
Choose "c3" by pressing
the ▲ and ▼ buttons, and
press the OK button.
A set value appears on the display.
Select a desired one by
pressing the ▲ and ▼
buttons.
The default is "_1".
Display
( Reverse rotations are
not counted.)
( The count is put back
by reverse rotations.)
( The count is reset by
reverse rotations.)
P. 22
Count return
OFF
Return 1 count*
Return to start
When it is set to "_1"
1
The 2nd screw is
redone.
(Reverse rotations)
* In a state where no screws are
fastened, reverse rotations will not
cause the count to go back beyond the
default.
* To reverse the rotation when the
number of screws set through the
count quantity is reached, set a waiting
time through " c7 Batch Complete
Judgement Waiting Time Setting".
P. 31
Press the OK button to
confirm it.
When the setting is completed, a
buzzer sounds long (a long beep),
and the display returns to the menu
screen.
Back to Operation Mode.
Hold down the OK button.
P. 22
2
The count
goes back
by one.
27