Signal Test; Calibrate; Go Back - Graco Pulse 26C935 Installation And Operation Manual

Metered dispense valve
Table of Contents

Advertisement

SIGNAL TEST

A signal test is performed to determine RF
signal strength once the Pulse HUB is
powered up, all extenders are registered to
the HUB and the PAN network is established.
The meter must be registered to the HUB
before a signal test can be performed. Signal
testing on a remote PAN network via the
Remote Extender requires that the meter be
registered through the Remote Extender and
not the Pulse HUB.
To perform the signal test:
1.
From the main screen use the UP and
DOWN arrow on the navigation pad to
select SET-UP.
F
. 46
IG
2.
Select SIGNAL TEST.
F
. 47
IG
3A7397E
3.
To test the signal at a particular location
use the navigation arrows to select and
highlight ACTIVATE. Press ENTER.
F
. 48
IG
The meter must be kept in a stationary
position during the signal test.
The test will take approximately 10 secs.
The output of the test will be a relative
signal strength symbol or the message
NO SIGNAL. For a robust network, every
Pulse device should be at a 2 bar signal
strength or better. Consider adding
additional Extenders if a device location
is at 1 bar or below.
There are several factors that affect and
impact the RF signal strength such as
overhead garage doors opening and
closing, vehicles on a lift, and large
vehicles in the RF pathway.
Press ENTER again to perform
additional tests.

CALIBRATE

Calibration of the metered dispense valve
assures that dispenses are accurate. See
Calibration instructions beginning on page
15.

GO BACK

Returns to the Main Menu Screen, page 14.