BRUEL & KJAER 1053 Instruction Manual page 47

Vibration exciter control
Table of Contents

Advertisement

Header
Min Code
Section
Action
Auto_Range
A_R
5.4.1
Brings the compressor display into range and sets
the vibration meter function
Charge_ Sensitivity_ Correction
c_s_c
5.4.2
Applies an input sensitivity correction (charge only)
Charge_ Sensitivity_ Correction?
C_S_C?
5.4.3
Gives the input sensitivity correction
'
Compressor
c
5.4.4
Switches the compressor on or off
Compressor?
C?
5.4.5
Gives the compressor on/off status
Compressor _Cross_ Over _Safety
c_c_o_s
5.4.6
Activates/deactivates the comp. cross over safety
Compressor _Cross_ Over _Safety?
C_C_O_S?
5.4.7
Gives the compressor cross over safety status
Compressor _Max_ Speed
C_M_S
5.4.8
Sets the max. compressor speed
Compressor _Max_ Speed?
C_M_S?
5.4.9
Reads out the max. compressor speed
Compressor _Rate
C_R
5.4.10
Sets the compressor rate
Compressor _Rate?
C_R?
5.4.11
Gives the compressor rate
Compressor _Safety _Limit
C_S_L
5.4.12
Sets the compressor safety limits
Compressor _Safety _Limit?
C_S_L?
5.4.13
Gives the compressor safety limits
Cross_ Over _Calculate
c_o_c
5.4.14
Calculates the cross over frequencies
Cross_ Over _Frequency_< M)
C_O_F_(M)
5.4.15
Sets the cross over frequency number M
Cross_ Over _Frequency_< M)?
C_O_F _(M)?
5.4.16
Gives the cross over frequency number M
Error?
E?
5.4.17
Gives the last error number
Error_Stop
E_S
5.4.18
Selects stop/continue of data transfer on an error
Error _Stop?
E_S?
5.4.19
Gives the data transfer on error status
Externai_Filter
E_F
5.4.20
Sets the vib. meter and compressor external filter
Externai_Filter?
E_F?
5.4.21
Gives the vib. meter and compressor external filter
Force_Level
F_L
5.4.22
Sets the vibration meter force level
Force_Level?
F_L?
5.4.23
Gives the vibration meter force level
Frequency
F
5.4.24
Sets the generator frequency
Frequency?
F?
5.4.25
Gives the generator frequency
Front_Panei_Enable
F_P_E
5.4.26
Enables/disables front panel
Front_Panei_Enable?
F_P_E?
5.4.27
Gives front panel enable/disable status
Front_Panei_Select
F_P_S
5.4.28
Selects a front panel number
Generator _Levei_Actual
G_L_A
5.4.29
Sets the actual generator level
Generator _Levei_Actual?
G_L_A?
5.4.30
Gives the actual generator level
Generator _Levei_Programmed
G_L_P
5.4.31
Sets programmed generator level
Generator _Levei_Programmed?
G_L_P?
5.4.32
Gives programmed generator level
Generator _Output
G_O
5.4.33
Switches on/off the generator output
Generator _Output?
G_O?
5.4.34
Gives the generator output status
Identify?
10?
5.4.35
Gives instrument identification "B&K 1 053"
lnput_Sens
I_S
5.4.36
Dummy Message for read in without error
lnput_Sens?
I_S?
5.4.37
Gives the input sensitivity setting
T01504GB2
Table 5.2 (a). List of interface Messages available in the 1053
39