DCS BH1-48RI Installation Manual page 9

Professional grill
Table of Contents

Advertisement

Gas Requirements
Do not change the regulator/hose assembly from that supplied with the unit or attempt
z
to use a Type 1 equipped regulator/hose assembly with a standard 510 POL cylinder/
valve assembly.
The cylinder pressure relief valve outlet must point away from the user when in use.
z
An installer-supplied gas shut-off valve must be installed in an easily accessible
z
location.
All installer supplied parts must conform to local codes, or in the absence of local
z
codes, with the National Electrical Code, ANSI/NFPA 70 or the Canadian Electrical
Code, CSA C22.1, and the National Fuel Gas Code, ANSI Z223.1 or CSA-B149.1 Natural
Gas Installation Code or CSA-B149.2 Propane Installation Code.
In Massachusetts such shut-off valves should be approved by the Board of State
z
Examiners or Plumbers & Gas Fitters.
All pipe sealants must be an approved type and resistant to the actions of LP gases.
z
Never use pipe sealant on flare fittings.
A dented or rusty LP cylinder may be hazardous and should be checked by your
z
LP supplier.
Always check for leaks after every LP cylinder change. Check with a full cylinder.
z
Do not use the appliance until all connections have been checked and do not leak.
z
Before each use, inspect the gas supply piping or hose prior to turning the gas ON. If
z
there is evidence of cuts, wear, or abrasion, it must be replaced prior to use.
The pressure regulator and hose assembly supplied with the appliance must be used. If
z
replacements are needed, contact Customer Care.
Storage and maintenance
Ensure the gas supply is turned off at the supply cylinder when not in use.
z
Keep appliance covered when not in use.
z
Storage of the appliance indoors is permissible only if the cylinder is disconnected and
z
removed from the unit.
Cylinders must be stored outdoors, out of reach of children and must not be stored in a
z
building, garage, or any other enclosed area.
After a period of storage or non-use, the appliance should be checked for gas leaks,
z
deterioration, proper assembly, and burner obstructions before use.
Keep the outdoor gas appliance area clear and free from combustible materials,
z
gasoline, and other flammable vapours and liquids.
Clean the outdoor gas appliance, including special surfaces with recommended
z
cleaning agents and check burner/venturi tubes for insects and insect nests. A clogged
tube can lead to a fire beneath the grill.
LP Cylinder Cabinet Requirements
For a cylinder enclosure having four sides, a top and a bottom, and intended for
installation in a built-in enclosure:
At least one ventilation opening shall be provided on the exposed exterior side of the
z
enclosure located within 5" (127mm) of the top of the enclosure and unobstructed. The
opening(s) shall have a total free area of not less than 1"²/lb (14.2cm²/kg) of stored
fuel capacity.
At least one ventilation opening shall be provided on the exposed exterior side of the
z
enclosure 1" (25.4mm) or less from the floor level and shall have a total free area of not
less than 1/2"²/lb (7.1cm²/kg) of stored fuel capacity. The upper edge shall be no more
than 5" (127mm) above the floor level.
Every opening shall have a minimum dimension so as to permit the entrance of a 3/16"
z
(4.8mm) rod.
SAFETY AND WARNINGS
9