INSTALLATION REQUIREMENTS FOR NATURAL GAS
Natural gas Installation and connection
Check with your local gas utility company or local codes for instructions on installing
z
gas supply lines. Be sure to check on type and size of run, and how deep to bury
the line. If the gas line is too small, the grill will not function properly. Any joint
or pipe sealant used must be an approved type and be resistive to the actions of
combustible gases.
Ensure that the regulator arrow points in the direction of gas flow away from the
z
gas supply.
The appliance must be isolated from the gas supply piping system by closing its
z
individual manual shut-off valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 PSIG (3.5 kPa).
The appliance and its individual shut-off valve must be disconnected from the gas
z
supply piping system during any pressure testing of that system at test pressures in
excess of 1.2 psi (3.5 kPa).
An installer-supplied gas shut-off valve must be installed in an easily
z
accessible location.
Use threading compound on male threads only.
z
Never use pipe sealant on flare fittings.
z
In Massachusetts such shut-off valves must be approved by the Board of State
z
Examiners or Plumbers & Gas Fitters.
All piping and hoses are to run away from the product and never against the
z
product surfaces.
Natural Gas: Operating pressure: 4.0" W.C. Supply Pressure 5" to 14" W.C. If in excess
z
of 14", a stepdown regulator supplied by installer is required.
All gas piping and connectors must conform to the Standard for Connectors for
z
Outdoor Gas Appliances and Manufactured Homes, ANSI Z21.75/CSA 6.27.
Total gas consumption of the grill with all burners on HI - Input rates BTU/Hr
MODEL
MAXIMUM
GRILL
ROTISSERIE
SEAR
SIDE BURNER
SMOKER BURNER
Servicing
Do not repair or replace any part of the appliance unless specifically recommended
z
in this guide. All other servicing should be undertaken by an authorized technician or
qualified person.
Only use the product with the type of gas specified on the rating plate. To change gas
z
type, a factory conversion kit is required.
BH1-36R
BH1-48R
89000
118000
25000
25000
14000
18000
3500
3500
BH1-36RI
BH1-48RI
88000
117000
25000
25000
14000
18000
24000
24000
BH1-48RS
123000
25000
14000
17000
3500
11