From the weight display, press MENU to access the setpoint setting.
MENU/ENTER: to enter a menu/confirm the data entry.
▲:
to modify the displayed figure or menu item.
◄:
to select a new figure or modify the displayed menu item.
ESC:
to cancel and return to the previous menu.
- : if the E/EC option is connected, it is possible to set 12 groups (classes) of different
values for the setpoint; otherwise it is possible to set only the first class. Valid values for relays
switching are selected by the E/EC position.
-  (from 0 to max full scale; default: 0): Setpoint; relay switching occurs when the weight
exceed the value set in this parameter. The type of switching is settable (see section OUTPUTS
AND INPUTS CONFIGURATION).
-  (from 0 to max full scale; default: 0): Hysteresis, value to be subtracted from the setpoint
to obtain contact switching for decreasing weight. For example with a setpoint at 100 and
hysteresis at 10, the switching occurs at 90 for decreasing weight.
WTAB ONLY:
:
when the weight is lower than this value the display shows  alternated to weight.
- 
:
- 
when the weight is higher than this value the display shows  alternated to weight.
These values are set to zero if the calibration is changed significantly (see sections
THEORETICAL CALIBRATION and REAL CALIBRATION (WITH SAMPLE WEIGHTS)).