Weight has to be set to zero before selecting operation type.
- Load the empty container on the scale;
- press TARE to display zero (net weight);
▫ WDESK – WINOX: press START, select and confirm with ENTER, appears on
the display;
▫ WTAB: press MODE, select and confirm with ENTER, appears on the display;
- insert sample pieces in the container and press ENTER;
- set the number of sample pieces just loaded and confirm with ENTER;
The instrument displays the average weight calculated for the single piece for 1 second (PMU in
1/1000 unit of measure) and then the number of pieces preceded by the letter (e.g.: ), the
system is now ready to start counting the pieces.
- Load pieces to be counted on the scale;
- press TARE to display zero (net weight);
- remove sample pieces;
▫ WDESK – WINOX: press START, select and confirm with ENTER, appears on
the display;
▫ WTAB: press MODE, select and confirm with ENTER, appears on the display;
- set the number of sample pieces just removed and confirm with ENTER;
The instrument displays the average weight calculated for the single piece for 1 second (PMU in
1/1000 unit of measure) and then the negative number of pieces subtracted preceded by the letter
(e.g.: ), the system is now ready to start counting the pieces.
Pressing START you can move from one display to another:
- total weight on scale: preceded by the letter (e.g.: );
- average unit weight calculated: preceded by the letter (e.g.: );
- number of pieces: preceded by the letter (e.g.: );
PIECE COUNTER
INCREASING OPERATION
DECREASING OPERATION
DISPLAY AND OPERATION
- 37 -