Technical Specifications - LAUMAS WTAB-R Installation And User Manual

Table of Contents

Advertisement

POWER SUPPLY and CONSUMPTION (VDC)
POWER SUPPLY and CONSUMPTION (VAC)
NO. OF LOAD CELLS IN PARALLEL and SUPPLY
LINEARITY / ANALOG OUTPUT LINEARITY
THERMAL DRIFT / ANALOG OUTPUT THERMAL
DRIFT
A/D CONVERTER
MAX DIVISIONS
(with measurement range: ±10 mV = sens. 2 mV/V)
MEASUREMENT RANGE
MAX SENSITIVITY OF USABLE LOAD CELLS
MAX CONVERSIONS PER SECOND
DISPLAY RANGE
NO. OF DECIMALS / DISPLAY INCREMENTS
DIGITAL FILTER / READINGS PER SECOND
RELAY LOGIC OUTPUTS
LOGIC INPUTS
SERIAL PORTS
BAUD RATE
HUMIDITY (non condensing)
STORAGE TEMPERATURE
WORKING TEMPERATURE
OPTOISOLATED ANALOG OUTPUT (OPTIONAL)
16 bit - 65535 divisions

TECHNICAL SPECIFICATIONS

- 8 -
12/24 VDC ±10%; 6 W (standard)
115/230 VAC; 50-60 Hz; 6 VA
(optional only for WDESK)
max 8 (350 ohm); 5 VDC / 120 mA
< 0.01% F.S.; < 0.01% F.S.
< 0.0005% F.S./°C; < 0.003% F.S./°C
24 bit (16000000 points)
±999999
±39 mV
±7 mV/V
300 conversions/second
±999999
0÷4 / x 1 x 2 x 5 x 10 x 20 x 50 x 100
0.012÷7 s / 5÷300 Hz
N.5 - max 115 VAC; 150 mA
(N. 4 – analog output version)
N.3 - optoisolated 5 - 24 VDC PNP
(N. 2 – analog output version)
RS485, RS232
2400, 4800, 9600, 19200, 38400, 115200
85%
-30°C +80°C
-20°C +60°C
0÷20 mA; 4÷20 mA (max 300 ohm);
0÷10 V; 0÷5 V; ±10 V; ±5 V (min 10 kohm)