Maximum Capacity; Tare Weight Zero Setting; Zero Value Manual Entry; Real Calibration (With Sample Weights) - LAUMAS WTAB-R Installation And User Manual

Table of Contents

Advertisement

: Maximum displayable weight (from 0 to max full scale; default: 0). When the weight exceeds
this value by 9 divisions, the display shows . To disable this function, set 0.
This menu may also be accessed directly from the weight display, holding down the
key for 3 seconds.
Perform this procedure after having set the THEORETICAL CALIBRATION data.
Use this function to set to zero the weight of the empty system after commissioning and then later
on to compensate zero variations due to the presence of product residues.
Procedure:
- Confirm the message  (Zero) by pressing ENTER .
- The weight value to be set to zero is displayed. In this phase all of the LEDs are flashing.
- Confirming once again, the weight is set to zero (the value is stored to the permanent memory).
- Press ▲ to display the value of the total weight reset by the instrument, given by the sum of all
of the previous zero settings.
WARNING: Perform this procedure only if it's not possible to reset the weighed structure tare, for
example because it contains product that can not be unloaded.
Set in this parameter the estimated zero value (from 0 to max 999999; default: 0).
After having performed the THEORETICAL CALIBRATION and TARE WEIGHT ZERO
SETTING, this function allows correct calibration to be done using sample weights of known
value and, if necessary, any deviations of the indicated value from the correct value to be
corrected.
Load onto the weighing system a sample weight, which must be at least 50% of the maximum
quantity to be weighed.

MAXIMUM CAPACITY

TARE WEIGHT ZERO SETTING

ZERO VALUE MANUAL ENTRY

REAL CALIBRATION (WITH SAMPLE WEIGHTS)

- 21 -
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wdesk-lWinox-rWinox-lWinox-2lWdesk-rWtab-l

Table of Contents