- It is recommended that the power supply negative pole be grounded (WDESK-D, WINOX,
WTAB: connect the earthing system to the dedicated external terminal ).
- It is possible to supply up to eight 350 ohm load cells or sixteen 700 ohm load cells.
- For 4-wire load cells, make a jumper between EX- and REF- and between EX+ and REF+.
- Connect terminal "– SUPPLY" to the RS485 common of the connected instruments in the event
that these receive alternating current input or that they have an optoisolated RS485.
- In case of an RS485 network with several devices it is recommended to activate the 120 ohm
termination resistance on the two devices located at the ends of the network, as described in
section RS485 SERIAL CONNECTION.
- Option E/EC: selects 12 groups of 5 setpoint.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
INPUT
supply
5-24 Vdc
RS485
(1) ANALOG OUTPUT OPTION
2 3 4
Current output:
max load 300 ohm
Voltage output:
min load 10 kohm
5 outputs: settable setpoint or remote output management via protocol.
3 inputs: settable to have the following functions: NET/GROSS WEIGHT, SEMI-AUTOMATIC ZERO,
PEAK, PRINT or REMOTE CONTROL (see section OUTPUTS AND INPUTS CONFIGURATION).
(1) If the analog output is present (ANALOG OUTPUT OPTION) the following is no longer available:
▫ IN3 input
▫ OUT5 output
▫ E/EC options
WARNING: connect power supply specified on the plate found on the back of the instrument.
In 115 V and 230 V versions, terminals "+ SUPPLY" and "– SUPPLY" generate continuous voltage
at 24 Vdc only to be used as power supply for instrument inputs.

ELECTRICAL CONNECTIONS

BASIC INFORMATION

WIRING DIAGRAM

RS232
12-24 Vdc
OUTPUTS
max 115 Vac
supply
150 mA
4-WIRE load cell connection
19 20 21 22 23 24
+
-
INPUTS
LOAD CELLS
supply
6-WIRE load cell
5-24 Vdc
connection
E OPTION
1
2
Buttons not included in the supply
- 9 -
WARNING! WDESK
115 V / 230 V OPTIONS
L N
1
115/230
24 VDC
VAC
OUTPUT
3
4 5 6 7
8
9 10
11
12
13
EC OPTION
7
6
5
8
4
9
3
10
2
11
12
1
7 8
14
15
16
8
4
to instrument
8 4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wdesk-lWinox-rWinox-lWinox-2lWdesk-rWtab-l

Table of Contents