POWER SUPPLY and CONSUMPTION (VDC)
NO. OF LOAD CELLS IN PARALLEL and SUPPLY
LINEARITY / ANALOG OUTPUT LINEARITY
THERMAL DRIFT / ANALOG OUTPUT THERMAL
DRIFT
A/D CONVERTER
MAX DIVISIONS
(with measurement range ±10 mV = sens. 2 mV/V)
MEASUREMENT RANGE
MAX SENSITIVITY OF USABLE LOAD CELLS
MAX CONVERSIONS PER SECOND
DISPLAY RANGE
NO. OF DECIMALS / DISPLAY INCREMENTS
DIGITAL FILTER / READINGS PER SECOND
RELAY OUTPUTS
DIGITAL INPUTS
SERIAL PORTS
BAUD RATE
HUMIDITY (non condensing)
STORAGE TEMPERATURE
WORKING TEMPERATURE
OPTOISOLATED ANALOG OUTPUT
16 bit - 65535 divisions
RELAY OUTPUTS
Equipment to be powered by 12-24 Vdc LPS or Class 2 power source.
CASTL
CASTLPG9
CASTLGUA (1)
CASTLTAST
CASTLTASTPG9 (2)
CASTLTASTATEX (3) IP67 box with external keypad. ATEX version
CASTLTASTGUA
(1)

TECHNICAL SPECIFICATIONS

IP67 BOX VERSIONS
IP67 box with transparent cover
IP67 box with transparent cover and six PG9 cable glands
IP67 box with transparent cover and six PVC fittings
IP67 box with external keypad
IP67 box with external keypad and six PG9 cable glands
IP67 box with external keypad and six PVC fittings
(2)
12/24 VDC (standard) ±10%; 5 W
max 8 (350 ohm); 5 VDC / 120 mA
< 0.01% F.S.; < 0.01% F.S.
< 0.0005% F.S./°C; < 0.003% F.S./°C
24 bit (16000000 points)
±999999
±19.5 mV
±3 mV/V
80 conversions/second
±999999
0 - 4 / x 1 x 2 x 5 x 10 x 20 x 50 x 100
0.080 – 7.5 sec / 5 – 80 Hz
N.4 - max 115 VAC ; 150mA
N.2 - optoisolated 5 - 24 VDC PNP
RS485, RS232
2400, 4800, 9600, 19200, 38400, 115200
85%
-30°C +80°C
-20°C +60°C
0÷20 mA; 4÷20 mA (max 300 ohm); 0÷10 V;
0÷5 V; ±10 V; ±5 V (min 10 kohm)
N. 4 - max 30 VAC, 60 VDC; 150 mA
- 5 -
II3GD
(zone 2, 22)
(3)