Perkins 2806A-E18TA Operation And Maintenance Manual page 104

Table of Contents

Advertisement

104
Maintenance Section
Fuel System Secondary Filter - Replace
2. Close drain plug (1) and tighten to a torque of
30 N·m (266 lb in).
2806D Water Separator Drain
Illustration 72
Typical example
1. Ensure that the engine is stopped. Open drain (1).
The drain is a self-ventilated drain. Catch the
draining water in a suitable container. Dispose of
the water properly.
2. Close drain (1).
NOTICE
The water separator is under suction during normal
engine operation. Ensure that the drain valve is tight-
ened securely to help prevent air from entering the
fuel system.
Fuel System Secondary Filter -
Replace
Fuel leaked or spilled onto hot surfaces or electri-
cal components can cause a fire. To help prevent
possible injury, turn the start switch off when
changing fuel filters or water separator elements.
Clean up fuel spills immediately.
Ensure that the engine is stopped before any servic-
ing or repair is performed.
Do not allow dirt to enter the fuel system. Thoroughly
clean the area around a fuel system component that
will be disconnected. Fit a suitable cover over any
disconnected fuel system components.
g03861130
Illustration 73
(A) 2806A and 2806C Primary fuel filter
(B) 2806A and 2806C Secondary fuel filter
The primary fuel filter and the secondary fuel filter
should be serviced together.
i10083208
SEBU9074-06
NOTICE
NOTICE
g06110392