SEBU9074-06
2806A and 2806C Secondary Fuel
Filter
Illustration 74
Typical example
1. Place a suitable container below the primary fuel
filter to catch any fluid that may spill. Clean any
split fluid. Clean the outside of the primary fuel
filter.
2. If equipped, ensure that the fuel supply valve is in
the OFF position. Open drain valve (3) and allow
the fuel to drain. then, close the drain valve (3).
3. Remove filter housing assembly (2) from filter base
(1).
Illustration 75
Typical example
4. Remove filter element (4) from filter housing (2)
g06110971
and discard the old filter element. Remove O ring
seal (5) from filter housing (2) and discard the old
O ring seal. Ensure that the filter housing is clean
and free from dirt.
Illustration 76
Typical example
5. Install a new filter element (4) into filter housing
(2). Ensure that element location point (7) is
correctly installed onto filter housing location point
(6).