54
Maintenance Section
Fluid Recommendations
• Cavitation of the water pump
For optimum performance, Perkins recommends a
50 percent by volume of glycol in the finished coolant
(also referred to as 1:1 mixture).
Note: Use a mixture that will provide protection
against the lowest ambient temperature.
Note: 100 percent pure glycol will freeze at a
temperature of −13 °C (8.6 °F).
Most conventional antifreezes use ethylene glycol.
Propylene glycol may also be used. In a 1:1 mixture
with water, ethylene and propylene glycol provide
similar protection against freezing and boiling. Refer
to Table 5 and refer to table 6 .
Table 5
Ethylene Glycol
Concentration
50 Percent
60 Percent
NOTICE
Do not use propylene glycol in concentrations that
exceed 50 percent glycol because of the reduced
heat transfer capability of propylene glycol. Use ethyl-
ene glycol in conditions that require additional protec-
tion against boiling or freezing.
Table 6
Propylene Glycol
Concentration
50 Percent
To check the concentration of glycol in the coolant,
measure the specific gravity of the coolant.
Note: Some commercially available coolants are
based on alternative fluids, such as 1, 3-propanediol
(beta-propylene glycol, PDO), glycerin (glycerol) or
mixtures of these alternatives with ethylene/
propylene glycols. At the time of publication of this
document no industry standard exists for coolants
based on these chemicals. Until such standard/
specifications are published and evaluated by
Perkins, use of PDO, glycerine or other alternative
coolants is not recommended in Perkins diesel
engines.
Coolant Recommendations
• ELC
• SCA
Supplement Coolant Additive
• ASTM
American Society for Testing and
Materials
Freeze Protection
−36 °C (−33 °F)
−51 °C (−60 °F)
Freeze Protection
−29 °C (−20 °F)
Extended Life Coolant
ELC - extended life coolant. A coolant that relies on
organic inhibitors for corrosion and cavitation
protection. Also called OAT coolant (Organic Acid
Technology).
SCA - supplemental coolant additive, concentrated
inorganic inhibitor package.
Extender - concentrated organic inhibitor package.
Conventional Coolant - a coolant that relies on
inorganic inhibitors for corrosion and cavitation
protection.
Hybrid Coolant - a coolant in which the corrosion and
cavitation protection is based on a mixture of organic
and inorganic inhibitors.
The following coolants are recommended for used in
Perkins diesel engines:
Preferred – Perkins ELC
Acceptable – A commercial heavy-duty antifreeze
that meets "ASTM D6210" or "ASTM D4985"
specifications.
NOTICE
Do not use a commercial coolant/antifreeze that only
meets the ASTM D3306 specification. This type of
coolant/antifreeze is made for light automotive
applications.
NOTICE
A commercial heavy-duty antifreeze that meets
"ASTM D4985" specification requires a treatment
with an SCA at the initial fill. Read the label or the in-
structions that are provided by the manufacturer of
the product.
NOTICE
A commercial heavy-duty antifreeze that meets either
"ASTM D4985" or "ASTM D6210" specification re-
quires the SCA concentration to be checked at 500-
hour service intervals.
Perkins recommends a 50% mixture of water and
glycol. This mixture of water and glycol will provide
optimum heavy-duty performance as an antifreeze.
This ratio may be changed to 40% water to 60%
glycol if extra freezing protection is required.
A mixture of SCA inhibitor and water is acceptable
but will not give the same level of corrosion, boiling
and, freezing protection as ELC. Perkins
recommends a 6 percent to 8 percent concentration
of SCA in those cooling systems. Distilled water or
deionized water is preferred.
SEBU9074-06