WIRING DIAGRAMS

This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will
continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation.
(Do not cut the ground terminal off under any circumstances.)
NOTE: Even if the fan is not purchased with the unit, it is still a good idea to bring power to the receptacle box (provided with the unit) in
case the fan is installed at a later date.
Note: If optional fan is not purchased, batteries are required in both remote receiver (4 x AA batteries) & remote hand held ( 3 x AAA
batteries) in order to operate appliance using the remote control.
GROUNDING LUG
PATTE DE MISE À LA TERRE
NUT
STAR
STAR
WASHER
WASHER
POWER
CORD
GROUND
GROUND
Remote
RECEIVER HEARTH MOUNT
MONTAGE DU RÉCEPTEUR
RECEIVER
920-636
Colour: Black on Grey - Size: Printed at 100% - 7.5'' x 5''
Material: 2 ml white polyester
Oct. 31/22: Created decal
CAUTION: Label all wires
prior to disconnection
when servicing controls.
Wiring errors can cause
improper and dangerous
operation.
NUT
LOCK
WASHER
#8 GROUND
LUG
FAN
DC
SPARKER
GREEN/
VERT
OPTIONAL FAN KIT
KIT DU VENTILATEUR EN OPTION
NEUTRAL/NEUTRE
GREEN/VERT
120V AC
LIVE/
SOUS
TENSION
FAN CONTROL MODULE (FCM)
110V OUT
120V AC
BLACK/NOIR
BLACK/NOIR
MOTOR
Caution: Ensure that the wires do
not touch any hot surfaces and are
away from sharp edges.
Regency
P33-10 Zero Clearance Direct Vent Gas Fireplace
®
installation
GREEN/VERT
WHITE/
BLANC
FAN THERMODISC
(NORMALLY OPEN)
POWER
FAN
AUX OUT
COM
FCM-COM
TH
WHITE/BLANC (-)
RED/ROUGE (+)
TPTH
WHITE/BLANC
GREEN/VERT
OPTIONAL
THERMOSTAT
EN OPTION
|
49
BLACK/NOIR
920-636
|