3.4

ELECTRICAL SPECIFICATION

POWER SUPPLY
Pump
Ego 2 (T) easy xx/40
Ego 2 (T) easy xx/60
Ego 2 (T) easy xx/80
Ego 2 (T) easy xx/100
Ego 2 (T) easy xx/120
ELECTRICAL SPECIFICATIONS OF INPUTS, OUTPUTS AND COMMUNICATION
To see inputs, outputs and communication functions see chapter 5 Setup and operation. Not all functions are
available in all versions!
3.4.2.1 ANALOG INPUTS AND OUTPUTS (SET1, SET2, SET3)
Only available in variant Ego 2 (T) easy C.
Connections can be used either as inputs or outputs, depending on how we set it. Pump has 3 connectors: SET1,
SET2 and SET3.
Input voltage
Output voltage
Module U: ~ 50 kΩ
Input impedance
Module C: ~ 100 kΩ
Input sink current
Galvanic isolation
Electrical properties
Rated voltage
230 VAC ± 15 %, 47-63 Hz
Pumps can operate at
power (���� = ����
reduced voltage with limited
Electrical properties
–1 - 32 VDC
When used as input.
0 – 12 VDC
When used as an output. Max. 5 mA load on individual output.
Open circuit detection – max source output impedance < 50 kΩ
0.5 mA additional load for most configurations.
0 – 33 mA
Common sink on COM, if used as output.
Voltage 4 kV up to 1 s, 275 V permanent.
Rated
power [W]
60
90
⋅ ����)
140
!"#
180
180
26
26
Rated current
Startup
(I
) [A]
max
0,5
0,75
Build-in
1,15
startup
circuit
1,5
1,55