www.ti.com
2 Electrical Specifications
2.1
Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted)
(2)
V
Supply voltage
DD
Voltage on any digital pin
Voltage on the pins RF_P, RF_N, DCOUPL1 and DCOUPL2
Voltage ramp-up rate
Input RF level
T
Storage temperature range
stg
T
Solder reflow temperature
solder
ESD
Electrostatic discharge rating
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All supply pins must have the same voltage.
(3) Maximum voltage is 3.9 V.
(4) Measured according to IPC/JEDEC J-STD-020C
(5) High-sensitivity UHF devices must be handled with special care to avoid ESD damage. TI is not responsible for damage to this device
caused by external ESD conditions. The following electrostatic discharge (ESD) precautions are recommended:
•
Protective outer garments
•
Handling in ESD-safeguarded work area
•
Transporting in ESD-shielded containers
•
Frequent monitoring and testing of all ESD-protection equipment
(6) Measured according to JEDEC STD 22, Method A114
(7) Measured according to JEDEC STD 22, C101C
(8) Measured according to JEDEC STD 22, Method A115A
2.2
Recommended Operating Conditions
V
Supply voltage
DD
T
Operating free-air temperature
A
2.3
General Characteristics
PARAMETER
Frequency range
(1)
Data rate
Device weight
(1) Optional Manchester encoding halves the data rate.
Copyright © 2009–2010, Texas Instruments Incorporated
(1)
(4)
(5)
TEST CONDITIONS
T
= –40°C to 105°C, V
= 1.8 V to 3.3 V
A
DD
The data rate step size is determined by the reference frequency –
see Data Rate Programming
Shaped MSK (also known as differential offset QPSK)
Submit Documentation Feedback
SWRS076B – 11-07-22-013 - APRIL 2009 – REVISED APRIL 2010
(6)
Human-Body Model (HBM)
(7)
Charged-Device Model (CDM)
(8)
Machine Model (MM)
I temperature suffix
T temperature suffix
Q temperature suffix
CC11x1-Q1
–0.3 V to 3.9 V
(3)
–0.3 V to (V
+ 0.3 V)
DD
–0.3 V to 2 V
120 kV/µs
10 dBm
–50°C to 150°C
260°C
±750 V
±200 V
±100 V
MIN
MAX
UNIT
1.8
3.6
V
–40
85
–40
105
°C
–40
125
MIN
TYP
MAX
UNIT
310
348
420
450
MHz
779
928
1.2
250
kBaud
26 to 250
0.0715
g
Electrical Specifications
5