PCI Channel Interface PWB Trace Capture Procedure

Perform a Trace

10-8
Load the PCI Channel Interface PWB Trace command when
software is installed and the PCI Channel Interface PWB PWB is
detected. This procedure is usually performed at the request of
Software Engineering or as part of a SPAR package.
To start the trace, perform the following:
1. Login as Administrator.
2. Select [System - Online Manager].
3. Select:
Channel Gateway - Enable
Input Device - Online
Input Control - Start
4. Submit a job from the host.
5. After the job is completely received by the Controller, select
Input Control - End.
6. Open a Terminal window.
7. Type
cd /opt/XRXnps/XRXgrpset/bin
8. and press <Enter>.
9. Type
./dspTrc > FileName.txt
10. and press <Enter>.
11. Type
ls -l
12. and press <Enter> to see the new file and the file size.
13. If the file size is greater than 1.44 MB, type
compress FileName.txt
14. and press <Enter>. If the file size is less than 1.44 MB, go
to "Export the trace file to floppy".