HE1B Basic Three-position Enabling Switches
3-position enabling switch to avoid hazards.
Ideal for installing in teach pendants and other enabling devices.
• Ergonomically-designed OFF-ON-OFF.
• Direct opening action mechanism for shifting from position 2 (ON) to
position 3 (OFF) (EN 60947-5-1/IEC 60947-5-1, Annex K).
• The switch does not turn ON while being released from position 3
(OFF when pressed) to position 1 (OFF when released) (IEC60204-1,
9.2.5.8).
• Reliable performance in compact and lightweight package.
HE1B
Mounting Style
Side Mounting
Top Mounting
• Minimum applicable load (reference value): 3V AC/DC, 5 mA
Ratings
Contact Ratings
Rated Insulation Voltage (Ui)
Rated Thermal Current (Ith)
Rated Voltage (Ue)
AC 50/60 Hz
Rated Current (Ie)
DC
Contact Configuration (3-position switch)
• Minimum applicable load (reference value): 3V AC/DC, 5 mA
(Applicable range is subject to the operating conditions and load.)

Specifications

Applicable Standards
Applicable Standards for Use
Operating Temperature
Relative Humidity
Storage Temperature
Pollution Degree
Contact Resistance
Insulation Resistance
Impulse Withstand Voltage
Operating Frequency
Mechanical Durability
Electrical Durability
Shock Resistance
Vibration Resistance
Terminal Style
Applicable Wire
Terminal Soldering Heat Resistance
Terminal Tensile Strength
Mounting Screw Recommended Tightening
Torque
Degree of Protection
Conditional Short-circuit Current
Direct Opening Force
Operator Strength
Weight (approx.)
Contact Configuration
HE1B-M1
1 contact (3-position)
HE1B-M1N
Resistive Load (AC-12)
Inductive Load (AC-15)
Resistive Load (DC-12)
Inductive Load (DC-13)
UL508 (UL recognized), CSA C22.2, No. 14 (c-UL recognized), IEC/EN 60947-5-1,
IEC/EN 60947-5-8 (TÜV approval), IEC/EN60947-5-1, UL508 (UL recognized),
CSA C22.2 No.14 (c-UL recognized)
ISO 12100-1, -2/EN12100-1, -2, IEC 60204-1 / EN 60204-1
ISO 11161 / prEN 11161, ISO 10218 / EN 775, ANSI/RIA R15.06, ANSI B11.19
–25 to +60°C (no freezing)
45 to 85% (no condensation)
–40 to +80°C (no freezing)
2
50 mΩ maximum (initial value)
100 MΩ minimum (500V DC megger)
2.5 kV
1,200 operations per hour
Position 1 → 2 → 1:
Position 1 → 2 → 3 → 1:
100,000 operations minimum
Operating extremes: 150 m/s
Damage limits:
Operating extremes: 5 to 55 Hz, amplitude 0.5 mm
Damage limits:
Solder terminal
1 cable, 0.5 mm
310 to 350°C, 3 seconds maximum
20N minimum
HE1B-M1:
HE1B-M1N: M2.6 screw / 0.4 to 0.6 N·m
IP40, except terminals (IEC 60529)
50A (250V) (Use 250V/10A fast-blow fuse for short-circuit protection.)
30N minimum (position 2 → 3)
250N minimum
6g
Part No.
Ordering No.
HE1B-M1PN10
HE1B-M1NPN10
30V
2A
1A
1,000,000 operations
100,000 operations
2
1,000 m/s
2
16.7 Hz, amplitude 1.5 mm
maximum
2
M3 screw / 0.5 to 0.8 N·m
Package Quantity
10
250V
5A
125V
250V
3A
1.5A
1.5A
0.75A
0.4A
0.2A
0.22A
0.1A
1 contact