HE6B Rectangular Three-position Enabling Switches
Specifications
IEC/EN60947-5-1
IEC/EN60947-5-8 (TÜV approval)
GS-ET-22 (TÜV approval)
Applicable Standards
UL508 (UL recgonized)
CSA C22.2 No.14 (c-UL recognized)
GB14048.5 (CCC approval)
ISO12100/EN ISO12100
IEC60204-1/EN60204-1
ISO11161/EN ISO11161
Applicable Standards
ISO10218-1/EN ISO10218-1
for Use
ANSI/RIA/ISO10218-1
ANSI/RIA/R15.06, ANSI B 11.19
ISO13849-1/EN ISO13849-1
Operating Temperature
–25 to +60°C (no freezing)
Relative Humidity
45 to 85% RH (no condensation)
Storage Temperature
–40 to +80°C (no freezing)
2 (inside panel, terminal side)
Pollution Degree
3 (outside panel, operator side)
Contact Resistance
50 mΩ maximum (initial value)
Between live and dead metal parts:
100 MΩ minimum (500V DC megger)
Insulation Resistance
Between terminals of different poles:
100 MΩ minimum (500V DC megger)
1.5 kV (3 position switch)
Impulse Withstand Voltage
2.5 kV (monitor switch)
Operating Frequency
1200 operations per hour
Position 1→2→1:
Mechanical Durability
Position 1→2→3→1:
minimum
100,000 operations minimum (rated load)
Electrical Durability
1,000,000 operations minimum
(24V AC/DC, 100 mA)
Operating extremes: 150 m/s
Shock Resistance
Damage limits: 500 m/s
Operating extremes: 5 to 55 Hz, amplitude 0.5 mm
Vibration Resistance
Damage limits: 16.7 Hz, amplitude 1.5 mm
Terminal Style
Solder terminal
Applicable Wire
1 cable, 0.5 mm
Solder Terminal
310 to 350°C, 3 seconds maximum
Heat Resistance
Terminal Tensile Strength
20N minimum
Locking Ring Recom-
0.5 to 0.8 N·m
mended Tightening Torque
Degree of Protection
IP65 (IEC 60529)
50A (125V): 3-position switch
(Use 120V/10A fast acting type fuse for short
Conditional Short-circuit
circuit protection.) (IEC 60127-1)
Current
50A (250V): monitor switch
(Use 250V/10A fast acting type fuse for short
circuit protection.) (IEC 60127-1)
Direct Opening Force
40N minimum (monitor switch)
Direct Opening Stroke
0.9 mm minimum (return monitor switch)
(when pressing the entire
4.0 mm minimum (depress monitor switch)
button surface)
250N minimum
Operator Strength
(when pressing the entire button surface)
Weight (approx.)
17g
Dimensions
47.7
22
24.6
15.6
5
5
10-0.5
11.3
11.3
2.5
29
4 4
16
18
1,000,000 operations minimum
100,000 operations
2
2
maximum
2
Mounting Hole Layout
29.4
±0.2
37.4
±0.2
Mounting
Screws
• Mounting screws: M3 screw × 2
(not attached and must be sup-
3
plied by the user)
• Mounting screw length: 5 to 6 mm
(panel thickness + gasket)
All dimensions in mm.
Ratings
Rated Insulation Voltage (Ui)
Rated Thermal Current (Ith)
Rated Voltage (Ue)
Resistive Load (AC-12)
AC
Inductive Load (AC-15)
3-position
switch
Resistive Load (DC-12)
DC
Inductive Load (DC-13)
Resistive Load (AC-12)
Return monitor
AC
Inductive Load (AC-15)
switch
Depress monitor
Resistive Load (DC-12)
DC
switch (NC)
Inductive Load (DC-13)
3-position switch
Contact
Return monitor switch
Configuration
Depress monitor switch
• Minimum applicable load (reference value): 3V AC/DC, 5 mA
(Applicable operation area depends on the operating conditions and load.)
TÜV ratings:
UL ratings:
3-position switch:
3 position switch:
125V AC/0.5A (Resistive)
AC-12 125V/0.5A
30V DC/1A (Resistive)
DC-12 30V/1A
30V DC/0.7A (Pilot Duty)
DC-13 30V/0.7A
Monitor switch:
Monitor Switch:
250V AC/0.5A (General use)
AC-15 250V/0.75A
30V DC/1A (General use)
DC-13 125V/0.22A
250V AC/0.75A (Pilot Duty)
DC-13 30V/2.3A
30V DC/2.3A (Pilot Duty)
Operating Characteristics
HE6B-M211
Position 1
Approx. 17N
: ON (closed)
: OFF (open)
(reference value)
(Without rubber boot)
(When pressing the center
of the operator)
Approx. 4N
±0.3
0
0.9
Travel
(mm)
NO1-C1
When pressing
the operator
NO2-C2
Position
11-12
1→2→3
21-22
NO1-C1
When releasing
the operator
NO2-C2
Position
11-12
2→1
21-22
NO1-C1
When releasing
the operator
NO2-C2
Position
11-12
3→1
21-22
Notes:
• When a rubber boot is used, the operating force depends on the operating
temperature.
• The operating force to move the button from position 2 to position 3 can
be changed. For details, contact IDEC.
Terminal Arrangement (bottom view)
HE6B-M211
IDEC Mark
11
C1
NO1 NC1
12
C2
NO2 NC2
• 3-position switch (Note): 2 contacts
• Return monitor switch: 1 contact, terminal nos. 11-12
• Depress monitor switch: 1 contact, terminal nos. 21-22
• There are no terminal nos. 11-22 and 21-22 for HE6B-M200.
Note: Use NO and C terminals for OFF
(NC terminal is not used.)
125V (monitor switch: 250V)
3A
30V
125V
250V
0.5A
0.3A
1A
0.7A
2.5A
1.5A
1.5A
0.75A
2.5A
1.1A
0.55A
2.3A
0.55A
0.27A
2 contacts
0 to 1 contact
0 to 1 contact
Position 2
Position 3
±0.3
±0.3
±0.5
±0.5
±0.5
2.3
3.0
3.6
4.0
5.0
21
22
ON
OFF 3-position switch