HE1G Grip Style Three-position Enabling Switches
Specifications
Applicable Standards
Applicable Standards for Use
Operating Temperature
Relative Humidity
Storage Temperature
Pollution Degree
Contact Resistance
Insulation Resistance
Impulse Withstand Voltage
Electric Shock Protection Class
Operating Frequency
Mechanical Durability
Electrical Durability
Shock Resistance
Vibration Resistance
Applicable Wire
Applicable Cable
Conduit Port Size
Terminal Tensile Strength
Terminal Screw Tightening Torque
Degree of Protection
Conditional Short-circuit Current
Direct Opening Force
Operator Strength
Weight (approx.)
Operating Characteristics
HE1G-21SM
Position 1
Terminal No.
1−2
Pressing
(position 1 to 2 to 3)
5−6
3−4
1−2
Releasing
(position 2 to 1)
5−6
3−4
1−2
Releasing
(position 3 to 1)
5−6
3−4
HE1G-21SMB
Position 1
Terminal No.
1−2
Pressing
(position 1 to 2 to 3)
5−6
3−4
1−2
Releasing
(position 2 to 1)
5−6
3−4
1−2
Releasing
(position 3 to 1)
5−6
3−4
+
Momentary Pushbutton: 1NO contact (terminal no. 7-8)
: contact ON (closed)
Notes:
• 3-position switches operate with direct opening action
• For the output of the enabling device, use terminals 1-2 and 3-4.
• The above operation characteristics show when the center of the button is pressed. Pressing the edge of a button turns on one contact
earlier than the other contact, causing a delay in operation.
20
IEC60947-5-1, EN60947-5-1 (TÜV approved),
JIS C8201-5-1, EN60947-5-8 (TÜV approved)
GS-ET-22 (TÜV approved), UL508 (UL listed), CSA C22.2 No. 14 (c-UL listed)
ISO12100-1, -2/EN12100-1, -2, IEC60204-1/EN60204-1, ISO11161/prEN11161,
ISO10218/EN775, ANSI/RIA R15.06, ANSI B11.19
Silicon rubber boot:
NBR/PVC Polyblend rubber boot: –10 to 60°C (no freezing)
45 to 85% (no condensation)
–40 to +80°C (no freezing)
3
100 mΩ maximum (initial value)
Between live and dead metal parts: 100 MΩ minimum (500V DC megger)
Between terminals of different pole: 100 MΩ minimum (500V DC megger)
2.5 kV (momentary pushbuttons: 1.5kV)
Class II (IEC 61140)
1,200 operations per hour
Position 1 → 2 → 1:
Position 1 → 2 → 3 → 1: 100,000 operations minimum
100,000 operations minimum
Operating extremes: 150 m/s
Damage limits:
Operating extremes: 5 to 55 Hz, amplitude 0.5 mm minimum
Damage limits:
0.14 to 1.5 mm
(AWG16-25)
2
Outside diameter ø7 to 13 mm
M20 (cable gland is supplied with the grip style enabling switch)
20N minimum
0.5 to 0.6 N·m
HE1G-21SM:
IP66 (IEC 60529)
HE1G-20ME:
IP65 (IEC 60529)
50A (250V) (Use 250V/10A fast-blow fuse for short circuit protection.)
90N minimum (3-position switch and monitor switch)
500N minimum (when pressing the entire button surface)
HE1G-21SM:
HE1G-20ME:
HE1G-20MB/HE1G-21SMB: 220g
Position 2
Position 3
Position 2
Position 3
: contact OFF (open)
when shifting from position 2 to position 3.
–25 to 60°C (no freezing)
1,000,000 operations minimum
2
1,000 m/s
2
16.7 Hz, amplitude 1.5 mm minimum
HE1G-20MB: IP65 (IEC 60529)
HE1G-21SMB: IP65 (IEC 60529)
210g
250g
HE1G-20ME
Position 1
Terminal No.
Pressing
1 − 2
(position 1 to 2 to 3)
3 − 4
Releasing
1 − 2
(position 2 to 1)
3 − 4
Releasing
1 − 2
(position 3 to 1)
3 − 4
+
Emergency Stop Switch: 2NC contact (terminal no. 5-6, 7-8)
HE1G-20MB
Position 1
Terminal No.
Pressing
1−2
(position 1 to 2 to 3)
3−4
Releasing
1−2
(position 2 to 1)
3−4
Releasing
1−2
(position 3 to 1)
3−4
+
Momentary Pushbutton: 2NO contact (terminal no. 5-6, 7-8)
Position 2
Position 3
Position 2
Position 3