Conforming to Standards
Operating Temperature
Storage Temperature
Operating Humidity
Altitude
Rated Insulation Voltage (Ui)
Impulse Withstand Voltage (Uimp)
Insulation Resistance
Electric Shock Protection Class
Pollution Degree
Degree of Protection
Operating Extremes
Vibration
Resistance
Damage Limits
Shock Resistance
Key Tensile Strength when Locked
Operating Speed
Positive Opening Travel
Positive Opening Force
Thermal Current (Ith)
Rated Operating Current (Ie)
Contact Opening Distance
Operating Frequency
Mechanical Life
Electrical Life
Conditional Short-circuit Current
Recommended Short
Circuit Protection
Rated Operating Voltage
Rated Current
Coil Resistance
Energizing Voltage
De-energizing Voltage
Continuous Applicable Voltage
Continuous Applicable Duration
Insulation Class
Rated Operating Voltage
Rated Current
Light Source
Lens Color
Weight
www.idec.com
Specifications
EN1088, IEC60947-5-1, EN60947-5-1
GS-ET-19
–20 to +40˚C (no freezing)
–40 to +80˚C
85% RH maximum (no condensation)
2,000m maximum
300V (between LED or solenoid and ground: 60V)
4 kV (between LED or solenoid and ground: 2.5 kV)
Between live and dead metal parts: 100 MΩ minimum
Between live metal part and ground: 100 MΩ minimum
Between live metal parts:
Between terminals of the same pole: 100 MΩ minimum
Class 1 (IEC61140)
3 (IEC60947-5-1)
IP67 (IEC60529)
10 to 55 Hz, amplitude 0.5 mm
2
60 m/s
(approx.6G)
2
1,000 m/s
(approx. 100G)
1,500N minimum
1 m/sec maximum
11 mm minimum
20N minimum
Main circuit: 10A, Auxiliary circuit: 3A
Rated operating voltage (Ue)
Resistive load (AC12)
AC
Inductive load (AC15)
Resistive load (DC12)
DC
Inductive load (DC13)
Resistive load (AC12)
AC
Inductive load (AC15)
Resistive load (DC12)
DC
Inductive load (DC13)
Main circuit: 1.7 mm max., Auxiliary circuit: 1.2 mm min.
900 operations/hour
1,000,000 operations
100,000 operations (rated load)
100A (IEC60947-5-1)
250V, 10A fuse (Type D01 based on IEC60269-1, 60269-2)
24V DC
415 mA
58Ω (at 20°C)
Rated voltage × 85% maximum (at 20°C)
Rated voltage × 10% minimum (at 20°C)
Rated voltage × 110%
Not specifically limited
Class B
24V DC
10 mA
LED lamp
Red or Green (12 mm dia. Lens)
660g
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC

Ordering Information

HS1C - R 1 4 4 R - R
100 MΩ minimum
Circuit Diagram No.
Blank:
1:
2:
3:
30V
125V
250V
10A
10A
6A
10A
5A
3A
6A
3A
0.9A
3A
3A
3A
3A
0.9A
HS1C Series
Indicator Color:
R (Red), G (Green)
Housing Color:
R (Red)
Solenoid & LED voltage:
4 (24V DC)
Main Circuit
Auxiliary Circuit
1NC+1NC
1NO/1NO
1NC+1NC
1NO
1NC+1NC
1NC+1NC
1NC+1NC
1NC