IDEC HS1L Series Instruction Sheet

Solenoid type safety switch

Advertisement

Quick Links

INSTRUCTION SHEET - HS1L Series
INSTRUCTION SHEET
Original Instructions
Solenoid Type Safety Switch
HS1L Series
Thank you for purchasing this IDEC product. Confirm that the delivered product is
what you have ordered. Read this instruction sheet to make sure of correct operation.
S A F E T Y P R E C A U T I O N S
In this operation instruction sheet, safety precautions are categorized in order of
importance to Warning and Caution :
WARNING
Warning notices are used to emphasize that improper operation may cause severe
personal injury or death.
CAUTION
Caution notices are used where inattention might cause personal injury or damage to
equipment.
1
Type
Circuit Code
Main
Door monitor
Lock monitor
circuit
circuit
R : 1NC + 1NC
1NC, 1NO
DQ : 1NC + 1NC
1NO
1NC + 1NC
DT : 1NC + 1NC
1NC
1NC + 1NC
[VR] :
2NC,1NO
[VQ] :
2NC,1NO
[VT] :
3NC
Solenoid voltage / Lock Mechanism
4 : 24V DC / Spring Lock
7Y : 24V DC / Solenid Lock
LED voltage
4 : DC24V
[0] : Without LED
Type Nos. in [ ] are not supplied as
standard. Contact IDEC if required.
CAUTION
Solenoid lock type
• This safety switch is designed to lock the actuator while the solenoid is energized
and to release it when deenergized.
• When the power to the solenoid is interrupted by accident, such as disconnection,
the lock is released before a machine stops ompletely. Then, the worker may be
exposed to hazards.
• This safety switch can be used only for limited applica ions which do not especially
need to be locked for safety.
HS 1L - R 4 4 K MS R P - G
Indicator Color
G : Green
R : Red
circuit
2NC
1NO
1NC
3NC
2NC,1NO
3NC
Mnual unlock key
[blank] : Without Manual Unlock Key
K : With Manual Unlock Key
Solenoid Type Safety Switch
2
Specifications and Ratings
Applicable Standards
Standards for Use
Interlocking device Type
/ the level of coded
Applicable Direc ives
Operating
Condition
Impulse withstand voltage ‹Uimp›
Rated insulation voltage ‹Ui›
Thermal Current ‹Ith›
Contact Ratings
(Reference Values)
‹Ue , Ie›
Class of Protection
Operating Frequency
Operating Speed
B10d
Mechanical Durability
Electrical Durability
Shock Resistance
Vibration Resistance
Actuator Tensile Strength
when Locked
Direct Opening Travel
Direct Opening Force
Contact Resistance
Degree of Protection
Conditional short circuit current
Short-circuit protective device
Rated Operating Voltage
Rated Current
Turn ON Voltage
Turn OFF Voltage
Rated Power Consumption
Rated Operating Voltage
Rated Current
Light Source
Lens Color
Weight
*1 Basic insulation of 4kV impulse withstand voltage is ensured between different
contact circuits and between contact circuits and LED or solenoid in the enclosure.
When both SELV (safety extra low voltage) or PELV (protective extra low voltage)
circuits and other circuits (such as 230V AC circuits) are used for the solenoid
power and contact circuits at the same time, the SELV or PELV requirements are
not met any more.
*2 See item 8 Dimensions.
*3 The actuator locking strength is rated at 3,000N of static load. Do not apply a load
higher than the rated value. When a higher load is expected to work on the
actuator, provide an addi ional system consisting of another safety switch without
lock (such as the HS5D safety switch) or a sensor to detect door opening and stop
the machine.
*4 F1max. is maximum force. The actuator's guard-locking force Fzh is calculated in
accodance with GS-ET-19:
*5 Make sure that a fast acting fuse for short-circuit protection trips before overheating
of the wires.
Ratings approved by safety agencies
(1) TÜV rating
AC-15 250V, 3A
DC-13 30V, 4A
EN ISO / ISO14119
IEC60947-5-1, EN60947-5-1
GS-ET-19, UL508, CSA C22.2 No.14
GB14048.5
IEC60204-1/EN60204-1
Type 2 Interlocking device
/ low level coded actuator (EN ISO / ISO14119)
Machinery Directive, Low Voltage Directive
Operating Temperature
-20 to +55°C (no freezing)
Operating Humidity
45 to 85% (no condensation)
Storage
Temperature
-40 to +80°C (no freezing)
Pollution Degree
3
Altitude
2000m maximum
4kV (Between ground and LED,solenoid circuit : 1.5kV)
300V (Between ground and LED,solenoid circuit : 30V)
10A
Resistive load(AC-12)
AC
Induc ive load(AC-15)
Resistive load(DC-12)
DC
Induc ive load(DC-13)
Class II (IEC61140) *1
900 operations/hour
0.05 to 1.0 m/s
2,000,000 (EN ISO 13849-1 Annex C Table C.1)
1,000,000 operations min. (GS-ET-19)
100,000 operations min.
(900 operations / hour, Rated Load)
1,000,000 operations min.
(900 operations / hour, 24V AC/DC 0.1A Resistive Load)
Damage Limits: 1,000m/s
2
Operating Extremes:10 to 55 Hz, half amplitude 0.35mm
Damage Limits: 30 Hz, half amplitude 1.5mm
Fzh=3,000N minimum
F1max.=3,900N minimum (GS-ET-19) *2, *3, *4
11mm min.
50N min.
50mΩmax. (Initial value)
IP67 (IEC60529)
100A (250V)
250V, 10A fast acting type fuse *5
24VDC 100%ED
200mA (Initial value)
Rated Voltage × 85% max. (at 20°C)
Rated Voltage × 10% min. (at 20°C)
Approx. 5W
24VDC
10mA
LED
R(Red), G(Green) (Φ12 Lens)
Approx. 450g
maximum force (F1max.)
=
Fzh
Safety coefficient (=1.3)
(2) UL, c-UL rating
A300 3A, 250V ac, Pilot Duty
4A, 30V dc, Pilot Duty
2016.08
B-1907-1(0)
30V 125V 250V
10A 10A
6A
10A
5A
3A
8A 2.2A 1.1A
4A 1.1A 0.6A
(3) CCC rating
3A, 250VAC
4A, 30VDC
( 1 / 6 )

Advertisement

loading

Summary of Contents for IDEC HS1L Series

  • Page 1 Machinery Directive, Low Voltage Directive Operating Temperature -20 to +55°C (no freezing) Thank you for purchasing this IDEC product. Confirm that the delivered product is Operating what you have ordered. Read this instruction sheet to make sure of correct operation.
  • Page 2: Mounting Examples

    INSTRUCTION SHEET - HS1L Series 2016.08 Solenoid Type Safety Switch B-1907-1(0) Actuator Mounting Reference Position Mounting Examples • As shown below, the mounting reference position of the actuator inserted into the safety switch is the actuator cover or stop film touches he safety switch lightly. (After •...
  • Page 3: Precautions For Operation

    B-1907-1(0) Precautions for Operation CAUTION • HS1L Series Safety Switches are Type 2 low-level coded interlocking devices (EN Installation ISO / ISO14119). The following system installation & mounting instructions are EN • Do not apply an excessive shock to the safety switch when opening or closing the ISO / ISO14119 requirements to prevent function failure from the interlock switch.
  • Page 4: Contact Operation

    INSTRUCTION SHEET - HS1L Series 2016.08 Solenoid Type Safety Switch B-1907-1(0) □ ( HS1L-V Contact Operation Door States Closed Closed Open Closed Manual Unlock Key Turn the key Contact Configuration and Operating Characteristic to unlock position Monitor Circuit 11-12 Type Contact Configuration *9...
  • Page 5 INSTRUCTION SHEET - HS1L Series 2016.08 Solenoid Type Safety Switch B-1907-1(0) Applicable Connectors Conduit Thread Use a connector with a degree of protection IP67. Applicable connector dimensions: See the figure on the right. • When using flexible conduit and metal connector Applicable Flexible Conduit Example: 9mm max.
  • Page 6: Dimensions (Mm)

    2-6-64 Nishimiyahara Yodogawa-ku, Osaka 532-0004, Japan EU Authorized Representative:IDEC Elektrotechnik GmbH Heselstuecken 8, D-22453 Hamburg, Germany DECLARATION OF CONFORMITY We, IDEC CORPORATION 2-6-64, Nishimiyahara Yodogawa-ku,Osaka 532-0004, Japan declare under our sole responsibility that the product: Description: Safety Switch Model No: HS1L to which this declaration relates is in conformity with the EC Directive on the following standard(s) or other normative document(s).

This manual is also suitable for:

Hs1l-r seriesHs1l-dq seriesHs1l-dt seriesHs1l-vr seriesHs1l-vq seriesHs1l-vt series