Specifications
Conforming Standards
Application Standards
Operating Temperature
Relative Humidity
Storage Temperature
Operating Environment
Impulse Withstand Voltage
Insulation Resistance
(DC megger)
Electric Shock Protection Class
Degree of Protection
Shock Resistance
Vibration Resistance
Actuator Operating Speed
Positive Opening Travel
Positive Opening Force
Tensile Strength when Locked
Operating Frequency
Mechanical Life
Electrical Life
Conditional Short-circuit Current
Cable
Cable Diameter
Weight (approx.)
Specifications
Locking Mechanism
Rated Voltage
Current
Coil Resistance
Operating Voltage
Return Voltage
Maximum Continuous Applying Voltage
Maximum Continuous Applying Time
Insulation Class

Current Ratings

Rated Insulation Voltage (Ui) (see note 2)
Current (Ith)
Rated Voltage (Ue)
Resistive load (AC12)
AC
Rated
Inductive Load (AC15)
Current (Ie)
Resistive load (DC12)
(see note 3)
DC
Inductive Load (DC13)
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
ISO14119, IEC60947-5-1, EN60947-5-1 (TÜV approval), EN1088, GS-ET-19
(BG approval), UL508 (UL recognized), CSA C22.2, No. 14 (c-UL recognized)
IEC60204-1/EN60204-1
–25 to 50°C (no freezing)
45 to 85% (no condensation)
–40 to +80°C (no freezing)
Degree of pollution: 3
2.5 kV (between LED, solenoid and grounding: 0.5 kV)
Between live and dead metal parts: 100 MΩ minimum
Between live metal part and ground: 100 MΩ minimum
Between live metal parts: 100 MΩ minimum
Between Terminals of the same pole: 100 MΩ minimum
Class II (IEC61140)
IP67 (IEC60529)
Operating extremes: 100 m/s
(10 G)
2
Damage limits: 1000 m/s
(100 G)
2
Operating extremes: 10 to 55 H, amplitude 0.35 mm minimum
Damage limits: 30 Hz, amplitude 1.5 mm minimum
0.05 to 1.0 m/s
Actuator HS9Z-A51: 11 mm minimum
Actuator HS9Z-A52/A55: 12 mm minimum
80N minimum
1000 N minimum (GS-ET-19)
900 operations per hour
1,000,000 operations minimum (GS-ET-19)
100,000 operations minimum (operating frequency 900 operations per
hour, rated load AC-12, 250V, 1A)
50A (250V) (Note: Use 250V/10A fast acting type fuse for short circuit
protection.)
UL2464, No. 21 AWG (8-core: 0.5 mm
or equivalent/core)
2
ø7.6 mm
400 g (HS5E-***01)
Spring Lock/Solenoid Lock
24V DC
266 mA
90Ω (at 20°C)
Rated voltage x 85% or less (at 20°C)
Rated voltage x 10% or more (at 20°C)
Rated voltage x 110%
Continuous
Class F
250V (between LED, solenoid and grounding: 30V)
2.5A
30V
125V
2A
1A
2A
0.4A
1A
0.22A
Part Number Key
HS5E -

Pilot Light

Rated Voltage
Current
Light Source
Light Color
1. Minimum applicable load (reference value): 3V AC/DC, 5 mA
250V
2. UL rating: 125V
1A
3. TUV, BG rating: AC-15, 0.5A/250V, DC-13, 0.22A/125V
UL, c-UL rating: Pilot duty AC 0.5A/125V, Pilot duty DC 0.22A/125V
0.5A
0.2A
0.1A
A
4 4 01 - G
Pilot Light Color
G (Green)
Cable Length
01: 1m
03: 3m
05: 5m
Pilot Light Voltage
4: 24V DC
0: without pilot light
Solenoid Unit Voltage/
Lock Mechanism
4: 24V DC/Spring Lock
7Y: 24V DC/Solenoid Lock
Circuit Code
Lock Monitor
Door Monitor
Circuit
Circuit
A: 1NC + 1NC
1NO + 1NO
B: 1NC + 1NC
1NO + 1NC
D: 1NC + 1NC
1NC + 1NC
24V DC
10 mA
LED
Green