Setup Menu 2Nd Level; Setup Menu 2Nd Level Parameters - Fronius TransPocket 180 RC HW Operating Instructions Manual

Robot option
Hide thumbs Also See for TransPocket 180 RC HW:
Table of Contents

Advertisement

Setup Menu 2nd Level

Setup Menu 2nd
Parameter
Level Parameters
Description
Software version
The complete version number of the current soft-
ware is divided across several displays and can
be viewed by turning the selection dial
Automatic shutdown (time Shut down)
If the device is not used or operated within a set
period of time, it automatically switches into
Standby mode
Pressing a button on the control panel switches off
Standby mode - the device is now ready for weld-
ing
Factory setting: OFF
Fuse
To display/set the fuse being used
Factory setting:
-
For grid voltage 230 V = 16 A
-
For grid voltage 120 V = 20 A
If a fuse is set on the power source, the power
source will limit the current drawn from the grid,
which prevents an immediate tripping of the power
circuit breaker
Relationship between set fuse and pre-heating current:
Grid voltage
230 V
120 V
Set
Pre-heating current
fuse
10 A
180 A
13 A
180 A
16 A
180 A
OFF
180 A
15 A
140 A
16 A
140 A
20 A
170 A
OFF
170 A
Range
Unit
5 - 60
Minutes
OFF
At
Ampere
230 V
10 / 13 /
16 / OFF
At
120 V:
15 / 16 /
20 / OFF
Duty cycle
35%
35%
35%
35%
35%
35%
35%
35%
29