5.16 SETUP WITH SPOOL GUN FOR GAS SHIELDED MIG WIRE
A.
Ensure that the Power Source On/Off switch located on the
rear of the Power Source is in the Off position.
B.
Fit the Euro Spool Gun to the Power Source using the
front panel EURO torch adaptor (refer also to section 5.02
Attaching the MIG Gun). Connect the 8 pin Remote Control
Plug to the 8 pin Remote Control Socket on the power
source. Ensure 8 pin plug is correctly fitted to the 8 pin
socket on front panel and collar on plug is tightened firmly.
Connect the MIG Gun Polarity Lead (8) to the positive
C.
welding terminal (+). If in doubt, consult the wire
manufacturer. Welding current flows from the Power
Source via DINSE terminals. It is essential, that the male
DINSE plug is inserted and turned securely to achieve a
sound electrical connection.
D.
Fit the correct Feed Roll in Spool Gun for the Gas Shielded
MIG wire being used.
E.
Switch the Power Source On/Off switch located on the rear
of the Power Source to the On position and ensure the
Digital Display on the Front Panel is illuminated.
F.
Select MIG Mode using the Process Selection Control
button. Refer to Section 5.15 for further information.
G.
Feed wire through the wire drive mechanism in the Spool Gun.
Spool Gun
42
|
CIGWELD.COM.AU
OPERATING MANUAL
230/240
Figure 5-25: Setup with Spool Gun for Gas Shielded MIG Wire
H.
Connect the work lead to the negative welding terminal
(-). If in doubt, consult the wire manufacturer. Welding
current flows from the Power Source via DINSE terminals.
It is essential, that the male plug is inserted and turned
securely to achieve a sound electrical connection.
I.
Fit the welding grade shielding gas regulator/flowmeter
to the shielding gas cylinder. Ensure that the shielding
gas hose connection is sufficiently tight at the regulator
connection. Refer to section 5.01 for the connection and
instruction of shielding gas regulator/flowmeter.
WARNING
Before connecting the work clamp to the work
piece make sure the mains power supply is
switched off.
CAUTION
Loose welding terminal connections can cause
overheating and result in the male plug being fused
in the terminal. Remove any packaging material
prior to use. Do not block the air vents at the front
or rear of the Welding Power Source.