5.11 Setup for SPOOL GUN MIG (GMAW) Welding with Gas Shielded Mig Wire

A. Select MIG mode with the process selection control (refer to Section 4.02.13 for further information).
B. Connect the Mig torch polarity lead to the positive welding terminal (+). If in doubt, consult the electrode
wire manufacturer. Welding current flows from the Power Source via Dinse type terminals. It is essential,
however, that the male plug is inserted and turned securely to achieve a sound electrical connection.
C. Fit the Euro Spool Gun to the power source using the front panel EURO torch adaptor (refer also to Section
5.02 Attaching the Tweco Fusion Mig Torch). Connect the 8 pin Remote Control Plug to the 8 pin Remote
Control Socket on the power source.
D. Connect the work lead to the negative welding terminal (-). If in doubt, consult the electrode wire
manufacturer. Welding current flows from the Power Source via Dinse type terminals. It is essential,
however, that the male plug is inserted and turned securely to achieve a sound electrical connection.
E. Fit the welding grade shielding gas regulator/flowmeter to the shielding gas cylinder (refer to Section 5.01)
then connect the shielding gas hose from the shielding gas regulator/flowmeter outlet to the quick connect
Shielding Gas Inlet fitting gas on the rear of the Transmig 255i Power Source. Ensure that the shielding
gas hose connection is sufficiently tight at the regulator connection and the quick connect fitting "locks"
into place correctly on the rear of the power source.
F. Refer to the Weld Guide located on the inside of the wirefeed compartment door for further information.
G. Select MIG mode with the process selection control (refer to Section 4.02.13 for further information).
H. Set the Spool Gun Switch located inside the wire drive compartment, to SPOOL GUN. Refer to 4.02.21 on
Page 4-7.
I. Set the Local/Remote Switch located in the wire drive compartment to Remote in order to be able to control
the wirespeed from the spool gun wirespeed control. Refer to 4.02.19 on Page 4-7.
!
CAUTION
!
Loose welding terminal connections can cause overheating and result in the male plug being fused in the terminal.
Remove any packaging material prior to use. Do not block the air vents at the front or rear of the Welding Power Source.
Spool Gun
Figure 5-13: Setup for Spool Gun Welding with Gas Shielded Mig Wire
MIG (GMAW) WELDING
WARNING
Before connecting the work clamp to the work make sure the mains power supply is
switched off.
Secure the welding grade shielding gas cylinder in an upright position by chaining it to a
suitable stationary support to prevent falling or tipping.
Shielding Gas Hose Fitted
with Quick Connect
Spool Gun Switch
MIG polarity lead
Positive Welding
Terminal (+)
Work Lead
5-12
OPERATING MANUAL
240VAC
15A Mains Supply
Note: For Maximum duty cycle to be achieved,
Supply Plug and Lead must be upgraded to
4mm
2
Supply Lead & 25A Supply Plug.
Refer to Specification Table on Page 2-5.
Remote Control
Socket
Negative Welding
Terminal (-)
Art # A-13932
Manual 0-5550