BLUEVENOM XF190
5.15 MIG (GMAW) MANUAL MODE AND SETUP WITH SPOOL GUN FOR
GAS SHIELDED MIG WIRE
B
A
Note: Refer to Manual MIG settings
A. Process Selection Button. Select MIG
B. Select Shielding Gas Type
Select the correct Shielding Gas Type for the MIG wire
being used.
Select Argon/Mixed Gas
C. Wire Diameter and Manual Mode Button. Select MAN
In Manual Mode, Voltage and MPM (Wire Speed) must be
manually set. When using the Tweco SGT250 Spool Gun
with the BLUEVENOM XF190 the remote wirefeed speed
control located on the Spool Gun is operational when the
REM is shown on the Digital Display.
Note: When using the SGT250 spool gun the Control knob located on the
machine panel will not adjust MPM (Wirefeed Speed), the MPM (Wirefeed speed)
can only be adjusted manually on the Spool Gun.
40
|
CIGWELD.COM.AU
OPERATING MANUAL
D
D. Control Knob
Turn clockwise to increase the value;
Turn anti-clockwise to decrease the value;
Turn slowly in order to adjust value in small increments.
Turn quickly in order to adjust value in larger increments.
A Quick Press of the Control Knob to select
Pre-Set Voltage (V+/-).
Note: Volts Trim is not available in MIG Manual Mode.
Note: When using the Tweco SGT250 Spool Gun with the BLUEVENOM XF190
the remote wirefeed speed control located on the Spool Gun is operational
when the REM is shown on the Digital Display.