Vacuum Pumps; Pump Status Indicator; Multiple Gas Monitoring - Honeywell Vertex M User Manual

Continuous gas monitor
Hide thumbs Also See for Vertex M:
Table of Contents

Advertisement

2.9 Vacuum Pumps

Two field-replaceable pumps provide a redundant vacuum source for the transport and sample
flow system. One pump in the system draws vacuum while the other is idle. The pump exhaust
connects to the manufacturing facility central toxic exhaust system.
Note: The exhaust line from the Vertex M should not exceed 50 feet.
The pumps are located in the bottom of the Vertex M system cabinet inside a sound-deadening
enclosure to reduce noise. Three cooling fans circulate air over the pumps.
The Vertex M system draws cooling air in through a filter mounted on the pump module access
door.

2.9.1 Pump Status Indicator

See Pump Status Indicator under "System Display Area" on page  82 for more information.

2.10 Multiple Gas Monitoring

A Vertex M system equipped with two or more types of Analyzer modules can monitor more
than one gas (or groups of gases such as hydrides or mineral acids) at a location. Each Vertex
M Analyzer module can monitor only one gas family (such as hydrides or mineral acids).
Vertex M
31
User Manual

Advertisement

Table of Contents
loading

Table of Contents