Assa Abloy Adams Rite eForce 150 Installation Instructions And User Manual page 6

Keyless entry

Advertisement

SETTING UP AND USING THE eFORCE 150
Table 3. Function to Set
Function to Set
Audible Feedback
Visual Feedback (LEDs)
Attempts Before Lockout
Lockout Time
Hold Open Time
Emergency Hold Open Time
Delete All User Codes
Reset All Features
Table 4. Code(s) to Delete
Code(s) to Delete
Delete Individual Code
Delete Range of Codes
Battery Replacement
NOTE: When the batteries start to get low, the eForce 150 will emit a 4 tone warning before allowing entry; if batteries are not
changed and become very low, unit will enter blackout mode. If this happens, users 6-152 will be locked out; only Master, Emergency,
and Supervisor Codes will allow access in this mode. No codes are lost during low power conditions or battery replacement.
1. Insert key into cylinder and turn 180° clockwise to release blocking plate.
CAUTION: Once loose, the battery cover is free to slide down and can fall; support with free hand to prevent this.
2. Insert included 5/64" Allen key in hole below cylinder then loosen screw two (2) full turns to release battery cover (Figure 14).
3. Unplug battery holder (Figure 15) and replace four (4) Size AA Alkaline batteries, ensuring proper polarity.
NOTE: Lithium batteries are recommended in climates reaching 20°F and below.
4. Plug battery pack into mating connector (Figure 16) then slide cover into place (Figure 16).
— If the cover gets stuck halfway up, you may need to rotate the battery holder 90°.
5. Insert included 5/64" Allen key in hole below cylinder to tighten screw and secure battery cover (Figure 14).
6. Enter a known user code to ensure the eForce 150 is functioning correctly, if not refer to "Troubleshooting" section.
FIGURE 14
6 of 8
(a)
(b)
Enter Authorization
Enter PCC
Code then #.
then #.
Master / Supervisor
Master / Supervisor
Master / Supervisor
Master / Supervisor
Master / Supervisor
Master / Supervisor
Master / Supervisor
Master / Supervisor
(a)
(b)
Enter Authorization
Enter PCC
Code then #.
then #.
Master
Master
Supervisor
FIGURE 15
Approved 2023-11-13
(c)
Enter Selection or Confirmation
then #. (Bold is default)
31
32
33
34
44
46
60
72
(c)
Enter Start of Range
then #.
61
3 to 150
3 to 150
62
6 to 150
FIGURE 16
1 (enable); 2 (disable)
1 (enable); 2 (disable)
1 to 255 (5 attempts)
1 to 255 (15 seconds)
1 to 9 (5 seconds)
1 to 9 (5 seconds)
60
72
(d)
Enter End of Range
then #.
4 to 150
7 to 150