INSTALLATION
Mount the eForce 150
1. Insert the proper length spindle into the output hub.
2. Slide the eForce150 onto the anchor plate; ensure spindle engages with cam plug
(Figure 12, MS 1850 configuration shown).
NOTE: The eForce 150 must sit flush on the door surface.
3. Secure with two (2) #10-32 x 5/8" pan head screws (Figure 13).
FIGURE 12
Install Batteries
See "Battery Replacement" section (page 6) for detailed instructions.
SETTING UP AND USING THE eFORCE 150
User Codes
NOTES
• In user mode, entries must be followed by the * key.
• Following 5 successive invalid code entries, the red LED flashes once and a tone indicates that the eForce 150 will not accept entries
for 15 seconds. One tone per second sounds during this time. Refer to "Programming Information" to change default settings.
USER CODE DESCRIPTIONS
• Master Code. Used to program any code or unlock the device in any condition.
The default Master code setting (1234) must be changed before programming additional user codes.
• Emergency Code. Unlocks the device in all conditions, including low battery or "blackout".
The default Emergency code setting (4321) must be changed prior to programming features and codes.
• Supervisor Code. Will unlock the eForce 150, including low battery conditions. Allows for programming every code except the Master code.
• Lockout Code. Enter to restrict Normal User codes (6-152) from gaining access (green LED flash + two tones + two additional tones).
Enter again to cancel Lockout Mode and allow normal access (green LED flash + two tones).
• Passage Code. Will cause the device to allow free ingress entry (green LED flash + 3 tones). Enter a second time to return to Normal
User Mode (green LED flash + 2 tones). Passage Mode operates when the battery is low and can be overridden by the Lockout code.
• Normal User Codes. Used to briefly unlock the device. A correct code entry is indicated by a green LED flashing once per second.
An incorrect code entry is indicated by red LED flash and 3 tones. Up to 144 different Normal User codes may be programmed.
These codes may not be programmed until after the default Master and Emergency codes have been reprogrammed.
• One-Time User Codes. Will unlock the device one time only. A correct code entry is indicated by a green LED flashing once per
second. An incorrect code entry is indicated by red LED flash and 3 tones. One-Time user codes may be programmed into locations
151 and 152. These codes may not be programmed until after the default Master and Emergency codes have been reprogrammed.