Download Print this page

Assa Abloy Adams Rite eForce 150 Installation Instructions And User Manual page 5

Keyless entry

Advertisement

SETTING UP AND USING THE eFORCE 150
Programming Information
NOTES
• Master and Emergency Codes (default 1234 & 4321) must be reprogrammed
from the factory pre-sets before user codes may be entered.
• If the Master Code is lost, the controller's Master and Emergency Codes may be reset to factory
defaults by pressing Reset and # for 10 seconds.
— Reset Button is on the top back of the unit, remove from door to access.
• The programming mode will exit automatically if it times out or an invalid code is entered
during programming (indicated by a red LED flash and a tone).
• All codes need to be entered twice for validation during programming. If the two entered codes
do not match, the eForce 150 will exit programming mode and the previous code will remain active.
• Emergency, Lockout, and Passage codes may be singly deleted, rendering these functions
completely un-operational (they will not return to default once deleted).
• LED's can be disabled in User Mode (PCC32) but will remain enabled in programming mode.
Yellow = programming mode. Green = successful entry. Red = input error or programming mode exited.
• Program Command Codes (PCC) are designated codes for programming specific features. See Tables 2, 3 & 4.
PROGRAMMING PROCESS
1. Hold # key until yellow LED flashes three times.
2. Release # key and the yellow LED will begin to flash continually.
3. Program as required. a)-d). See Tables 2, 3 & 4.
4. To continue programming, press # within 2 seconds and return to step 3b.
5. When programming sequence is complete, wait for the device to time out and return
to normal operating mode, OR press the * key to exit programming mode.
6. Wait 2 seconds before entering any code
Example: Re-program Master Code-
Hold # →1234# →51# →1# →New Master # →New Master #
Table 2. Code to Set
Code to Set
Master
Emergency
Supervisor
Lockout
Passage
Normal User
One-Time User
(a)
(b)
Enter Authorization
Enter PCC
Code then #.
then #.
Master
Master
Master
Master / Supervisor
Master / Supervisor
Master / Supervisor
Master / Supervisor
Approved 2023-11-13
(c)
Enter Location
then #.
1
2
3
51
4
5
6 to 150
151 to 152
(d)
Enter New Code
then #. Repeat
4 to 7 digits
4 to 7 digits
4 to 7 digits
4 to 7 digits
4 to 7 digits
2 to 7 digits
2 to 7 digits
5 of 8

Advertisement

loading

This manual is also suitable for:

3090